Building construction — Accessibility and usability of the built environment
This document specifies a range of requirements and recommendations for the elements of construction, building assemblies, components, fittings and products that relate to the design and constructional aspects of usability and accessibility of buildings, i.e. access to buildings, circulation within buildings, egress from buildings during normal conditions, and evacuation in the event of a fire.…
Cadre bâti — Accessibilité et usage de l’environnement bâti
Le présent document spécifie un éventail d’exigences et de recommandations applicables aux éléments et assemblages de construction ainsi qu’aux composants, accessoires et produits liés aux aspects d’usage et d’accessibilité à considérer lors de la conception et de la construction de bâtiments, à savoir l’accès aux bâtiments, la circulation à l’intérieur des bâtiments, la sortie des bâtiments en…
Plugs, socket-outlets and couplers with arcuate contacts
1 Scope
This document sets the general and dimensional interchangeability requirements for plugs,
socket-outlets, connectors and appliance inlets with arcuate contacts of standardized
configurations (hereinafter referred to as accessories), with a rated operating voltage not
exceeding 600 V AC at a frequency of 50 Hz and 60 Hz and with rated currents of 20 A and
30 A, primarily intended for…
Benchmark energy factor assessment of slurry pumping systems
1 Scope
1.1 Inclusions
This Standard is intended for industrial slurry pumping systems with the following characteristics:
a)
electrically driven single and multi-stage slurry pumps;
b)
flowrate greater than 10 L/s;
c)
average particle size (d50) between 50 µm and 8 mm;
d)
settling slurry;
e)
slurry behaving as a viscous Newtonian fluid (shear stress is linear and proportional to…
1 Scope
1.1 The requirements of this Standard apply to Grades A and B acrylic-polymer-coated, siliconepolymer-
coated, or vinyl-polymer-coated electrical sleeving that consists of closely woven fabric made
from glass (see Table 1 for materials and ratings) and intended for use in equipment designed to be
installed and used in accordance with the rules of CSA C22.1, Canadian Electrical Code,…
Ideal state benchmarking and application of benchmark energy factor for data centres
1 Scope
1.1
This Standard specifies the framework and calculation models for “essential energy benchmarking” of data centres as a new form of ideal-state benchmarking for energy performance. It provides the specifications necessary to benchmark the energy efficiency performance of a data centre by using a dimensionless indicator called the benchmark energy factor (BEF).
This Standard is a…
1 Scope
This document provides the requirements and test methods for the safety performance of high pressure gas valves that are used in gaseous hydrogen stations of up to the H70 designation.
This document covers the following gas valves:
— check valve;
— excess flow valve;
— flow control valve;
— hose breakaway device;
— manual valve;
— pressure safety valve;
— shut-off valve.
NOTE…
Natural gas vehicle fuelling station compressor packages
1 Scope
1.1 Inclusions — Compressor packages
This Standard describes the general requirements for compressor packages used in compressed natural gas fuelling station service.
1.2 Inclusions — Compressor designs
This Standard applies to compressor designs referenced in Clause 5.
1.3 Pressure references
All references to pressure throughout this Standard are to be considered gauge pressures…
Méthode d’essai normalisée de la résistance au vent des assemblages de toiture végétalisée
1 Portée
1.1 Généralités
La méthode d’essai de la présente norme détermine la résistance au vent des assemblages de toiture végétalisée lorsqu’ils sont soumis au flux dynamique du vent et à l’arrachement sous l’action du vent dans des conditions de laboratoire.
1.2 Applicabilité
Les essais effectués conformément à la méthode d’essai de la présente norme s’appliquent aux systèmes de toiture…
Profile polypropylene (PP) storm sewer pipe and fittings
1 Scope
1.1 General
This Standard specifies requirements for open profile polypropylene (PP) storm sewer pipe and fittings for leak-proof applications.
Profile wall pipe includes only open profile with smooth interior and sizes based on controlled inside diameter. Open profile pipe is of an annular construction.
Notes:
1)
Pipe and fittings manufactured in accordance with this Standard…