Systems and software engineering — Life cycle processes — Risk management
This document:
— provides risk management elaborations for the processes described in ISO/IEC/IEEE 15288 and ISO/IEC/IEEE 12207,
— provides the users of ISO/IEC/IEEE 15288, ISO/IEC/IEEE 12207 and their associated elaboration standards with common terminology and specialized guidance for performing risk management within the context of systems and software engineering projects,
—…
Optical fibre cables - Part 1-2: Generic specification - Basic optical cable test procedures - Gener...
IEC 60794-1-2:2021 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 60794-1-2:2021 applies to optical fibre cables for use with telecommunications equipment and devices employing…
Systems and software engineering - Life cycle processes - Risk management
This document:
— provides risk management elaborations for the processes described in ISO/IEC/IEEE 15288 and ISO/IEC/IEEE 12207,
— provides the users of ISO/IEC/IEEE 15288, ISO/IEC/IEEE 12207 and their associated elaboration standards with common terminology and specialized guidance for performing risk management within the context of systems and software engineering projects,
—…
Optical fibre cables - Part 1-2: Generic specification - Basic optical cable test procedures - Gener...
IEC 60794-1-2:2021 applies to optical fibre cables for use with telecommunications equipment and devices employing similar techniques, and to cables having a combination of both optical fibres and electrical conductors. An objective of this document is to define general requirements and methodology guidance applicable to all of the cable test methods of IEC 60794-1 (all parts). A second objective…
Wildland firefighting personal protective equipment — Requirements and test methods — Part 6: Footwe...
This document covers the general design, minimum performance requirements and methods of test for wildland firefighting footwear. This document does not cover PPE for structural firefighting (see ISO 11999 series), for use against chemical, biological, radiological and nuclear hazards, ISO 18639 series PPE for firefighters undertaking specific rescue activities or for use where a reflective outer…
High-voltage switchgear and controlgear - Part 312: Guidance for the transferability of type tests o...
IEC TR 62271-312:2021(E) refers to high-voltage / low-voltage prefabricated substations (hereinafter prefabricated substations) as specified in IEC 62271-202:2014.
This document, among other options as agreed between manufacturer and user, can be used for the transferability of type tests performed on one or more prefabricated substations with a defined set of ratings and arrangement of…
Performance requirements for climate resilience of low slope membrane roofing systems
1 Scope
1.1
This Standard outlines requirements for low slope membrane roofing systems (LSMRS) when identified as “silver” and “gold” performance level based on the climate severity and resilience requirements.
Note: The National Building Code of Canada and the National Energy Code of Canada for Buildings provides “bronze” requirements for LSMRS.
1.2
This Standard is intended to be used by…
Compressed natural gas refuelling stations installation code
1 Scope
1.1 Inclusions
This Code applies to all compressed natural gas (CNG) refuelling stations, including those that are fixed or mobile and intended for private or public dispensing operations.
1.2 Exclusions
This Code does not apply to
a)
refuelling vehicles with liquefied natural gas (LNG). Refuelling vehicles with LNG is addressed in CSA B108.2. However, when an LNG facility has…
Liquefied natural gas refuelling stations installation code
1 Scope
1.1 Inclusions
This Code applies to
a)
the design, location, construction, operation, operator training, and maintenance of LNG refuelling stations, including LNG mobile refuelling units (MRUL), with single containment storage tanks up to 265 m3 (70 000 gal) water capacity employed for vehicle LNG dispensing operations;
b)
shop-fabricated and assembled refuelling stations when used…
1 Scope
1.1 General
This Code sets out the minimum provisions for the installation, extension, alteration, and renewal of hydronic heating systems.
1.2 Inclusions
This Code applies to open and closed hydronic heating systems. These systems include
a)
hydronic space heating;
b)
radiant heating (wall, floor, and ceiling);
c)
convectors;
d)
fan coils;
e)
combination potable-water-…