Plastics hoses — Helical-thermoplastic-reinforced thermoplastics hoses for suction and discharge of ...
ISO 3994:2007 specifies the requirements for three types of helical-thermoplastic-reinforced thermoplastics hoses for suction and discharge of water, weak aqueous chemical solutions and abrasive solids and slurries, for use in the ambient temperature range from -10 °C to +55 °C.
The three types of hose are for light-, medium- and heavy-duty applications.
The types of hoses covered in the standard…
1 Scope
1.1
This Standard specifies material and fabrication requirements for corrugated steel pipe, spiral rib pipe, and structural plate corrugated steel pipe products.
1.2
This Standard applies to the use of corrugated steel pipe, spiral rib pipe, and structural plate corrugated steel pipe for applications such as culverts, storm sewers, sanitary sewers, subdrains, ground recharge systems,…
1 Scope
1.1
This Standard provides performance requirements and test methods for evaluating the visibility, legibility, and power consumption of internally lighted exit signs. Visibility requirements have been developed based on assumed normal visual acuity and normal colour-sightedness in clear air at a maximum viewing distance of 30.5 m (100 ft).
Notes:
(1) The Scope does not imply that…
1 Scope
1.1
This Standard specifies
(a) performance requirements for factory-made household dehumidifiers with a rated daily water-removal capacity of up to 87.5 L (185 U.S. pints); and
(b) uniform procedures for measuring capacity and minimum energy factor, EF.
1.2
In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in…
STANDARD CORNER WALLMETHOD OF TEST FORFLAMMABILITY CHARACTERISTICSOF NON-MELTING FOAM PLASTICBUILDIN...
1. SCOPE
1.1 This method of test for flammability characteristics is applicable to certain low
density insulating materials that do not melt or drip during exposure to fire (see Appendix A). It
is used in establishing the Flame Spread Classification for those foamed plastics whose
flammability assessment by CAN/ULC-S102 requires the use of the rate formula FSV = 92.5 d/t
but where the…
Measurement of the average viscometric degree of polymerization of new and aged cellulosic electrica...
Describes a standardized method for the determination of the average viscometric degree of polymerization (DPv) of new and aged cellulosic electrically insulating materials. It may be applied to all cellulosic insulating materials such as those used in transformer, cable or capacitor manufacturing. The methods described can also be used for the determination of the intrinsic viscosity of…
Rubber, vulcanized or thermoplastic — Determination of tension set under constant elongation, and of...
ISO 2285:2007 specifies a number of methods of determining the dimensional changes in test pieces of vulcanized or thermoplastic rubber during and after tensile loading for relatively short periods under constant elongation or constant loading.
The constant-elongation test is intended to measure the ability of rubbers to retain their elastic properties after extension, at a standard laboratory…
1 Scope
This standard describes the apparatus, test methods, and formulas to be used in carrying out the tests and calculations required by wire and cable standards.
Note: Specific acceptance requirements are found in individual product standards.
Liquefied Natural Gas (LNG) - Production, Storage, and Handling
1 Scope
1.1
This Standard applies to the
(a) design;
(b) location;
(c) construction;
(d) operation; and
(e) maintenance
of facilities for the liquefaction of natural gas and facilities for the storage, vaporization, transfer, handling, and truck transport of LNG. It also contains requirements for the training of personnel.
1.2
For facilities that load or unload LNG from a marine…
STANDARD METHODS OF
FIRE ENDURANCE TESTS OF
BUILDING CONSTRUCTION AND MATERIALS
1. SCOPE
1.1 This Standard covers fire endurance tests applicable to walls, partitions, floors,
roofs, ceilings, columns, beams, and girders, as well as to some components of these building
sub-assemblies.
Note: It should be recognized that the performance displayed by a component in one assembly would
not necessarily be the same when such component is tested in a dissimilar assembly.
1…