Energy Performance and Capacity of Household Refrigerators, Refrigerator-Freezers, Freezers, and Win...
1 Scope
1.1
This Standard applies to compact and household refrigerators, refrigerator-freezers, freezers, wine chillers, and hybrid wine chillers that are electrically operated on a 60 Hz alternating current, with a nominal supply voltage of 115 V.
1.2
This Standard applies to
(a) refrigerators and refrigerator-freezers with a maximum capacity of 1100 L (39 ft3);
(b) freezers with a maximum…
Site Preparation, Foundation, and Anchorage of Manufactured Homes
1 Scope
1.1
This Standard applies to manufactured and modular homes designed to be supported on longitudinal floor beams.
Note: For simplicity, the term "manufactured home" is used in this Standard to refer to both manufactured homes and modular homes.
1.2
This Standard includes requirements for the following aspects of manufactured home installation:
(a) site preparation;
(b)…
1 Scope
1.1
This Standard describes essential elements and methods in the safe handling, transportation, and biological decontamination of contaminated reusable medical devices.
Note: The biological decontamination process includes thorough cleaning and, whenever necessary for personnel or patient safety, appropriate application of a disinfection process.
1.2
This Standard includes requirements…
Material Requirements for Concrete Containment Structures for CANDU Nuclear Power Plants
1 Scope
1.1
This Standard specifies requirements for the materials used in concrete containment structures of containment systems designated as class containment components, parts, and appurtenances in CANDU nuclear power plants.
1.2
In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard;…
Requirements for Safety-Related Structures for CANDU Nuclear Power Plants
1 Scope
1.1
This Standard provides material, design, construction, fabrication, inspection, and examination requirements for safety-related structures for CANDU nuclear power plants. Safety-related structures covered in this Standard are
(a) structures that support, house, or protect nuclear safety systems;
(b) components of structures that are required for the safe operation and/or safe…
Management of Low- and Intermediate-Level Radioactive Waste
1 Scope
1.1
This Standard specifies requirements for the management of low- and intermediate-level radioactive waste in solid, liquid, or gaseous states.
1.2
This Standard applies to organizations and facilities that generate, possess, manage, and transport lowand intermediate-level radioactive waste, including power reactors, research institutes, laboratories, and industrial facilities…
O80.0-08
General requirements for wood preservation
1 Scope
1.1
The CSA O80 Series of Standards specifies requirements related to the preservation and fire retardance of wood through chemical treatment (pressure and thermal impregnation). The subjects covered include materials and their analysis, pressure and thermal impregnation procedures, and fabrication and installation to put treated…
Shielded Power Cable for Commercial and Industrial Applications, 5-46 kV
1 Scope
1.1
This Standard applies to the materials, construction, and testing of one- to four-conductor cross-linked polyethylene and ethylene propylene rubber-insulated shielded power cables, rated 5 to 46 kV, that are used for the distribution of electrical energy under normal conditions of installation and service in indoor, outdoor, aerial, underground, or underwater locations.
1.2
This…
Cardiovascular Implants and Artificial Organs - Haemodialysers, Haemodiafilters, Haemofilters and Ha...
This National Standard of Canada is based on International Standard ISO 8637:2004.
1 Scope
This International Standard specifies requirements for haemodialysers, haemodiafilters, haemofilters and haemoconcentrators, hereinafter collectively referred to as "the device", for use for humans.
This lnternational Standard is not applicable to
- extracorporeal blood circuits,
-…
Cardiovascular Implants and Artificial Organs - Extracorporeal Blood Circuit for Haemodialysers, Hae...
This National Standard of Canada is based on International Standard ISO 8638:2004.
1 Scope
This International Standard specifies requirements for single-use extracorporeal blood circuits (hereafter referred to as "the device") and (integral and non-integral) transducer protectors which are intended for use in haemodialysis, haemodiafiltration and haemofiltration.
This International…