1 Scope
1.1 General
This Standard specifies requirements for workplace electrical safety necessary for the practical safeguarding
of workers during activities such as the installation, inspection, operation, maintenance, and demolition of
electric conductors and electric equipment, as well as work in proximity of energized electrical equipment.
1.2 Application
While it can be applied by…
1 Scope
1.1
This Code sets out the minimum provisions for the installation, extension, alteration, and renewal of
hydronic heating systems.
1.2
This Code applies to open and closed hydronic heating systems. These systems include
(a) hydronic space heating;
(b) radiant heating (wall, floor, ceiling);
(c) convectors;
(d) fan coils;
(e) combination potable water heating and space heating (combo)…
ICT Greenhouse Gas Reduction Project Protocol: Quantification and Reporting Version 1
Recognizing the impact of ICT on the environment and the increasing attention being
placed on sourcing ICT with a low environmental footprint, CANARIE funded a project to
initiate a consortium of industrial and commercial enterprises, universities, and
government agencies with the common goal of reducing GHG emissions associated with
ICT services. Part of this project included the development…
1 Scope
1.1
This Standard specifies energy efficiency and performance requirements for LED luminaires of the
directional and non-directional type used for general illumination, including those with a significant
decorative function.
1.2
This Standard does not cover LED products
(a) intended for indication, e.g., traffic lights and exit signs;
(b) exclusively intended for decoration, e.g.,…
Charities – Governance and Best Management Practices
1 PURPOSE
This standard specifies the requirements with respect to the governance and best management
practices for charitable organizations.
2 SCOPE
This standard applies to all charities registered with the Canada Revenue Agency that want to
implement and maintain best management practices.
This document was developed to serve as a reference document for conformity assessment activities
of…
Explosive atmospheres - Part 35-2: Caplights for use in mines susceptible to firedamp - Performance ...
IEC 60079-35-2:2011 details those performance and other safety features of caplights, including those with a point of connection for another equipment, not covered in IEC 60079-35-1, but which are important for the safety and working conditions of the user. It may also be applied to caplights for use in mines not likely to be endangered by firedamp. This first edition of IEC 60079-35-2 cancels…
Household and similar electrical appliances — Safety — Part 2-61: Particular requirements for therma...
1 Scope
This clause of Part 1 is replaced by the following.
This International Standard deals with the safety of electric thermal-storage room heaters
for household and similar purposes that are intended to heat the room in which they are
located, their rated voltage being not more than 250 V for single-phase appliances and 480 V
for other appliances.
Appliances not intended for…
Household and similar electrical appliances — Safety — Part 2-65: Particular requirements for air-cl...
1 Scope
This clause of Part 1 is replaced by the following.
This International Standard deals with the safety of electric air-cleaning appliances for
household and similar purposes, their rated voltage being not more than 250 V for singlephase
appliances and 480 V for other appliances.
Appliances not intended for normal household use but that nevertheless may be a source of
danger to…
Arc welding equipment — Part 1: Welding power sources
1 Scope
This part of IEC 60974 is applicable to power sources for arc welding and allied processes
designed for industrial and professional use, and supplied by a voltage not exceeding that
specified in Table 1 of IEC 60038, or driven by mechanical means.
This part of IEC 60974 specifies safety and performance requirements of welding power
sources and plasma cutting systems.
This part of IEC…
Toilettes chimiques, autonomes et à recirculation pour véhicules de camping
1 Domaine d’application
1.1
Cette norme vise les toilettes chimiques, autonomes et à recirculation et précise les exigences visant
a) la conception ;
b) les matériaux ;
c) les composants ;
d) la construction et le fini ;
e) les essais ;
f) l’installation ;
g) le fonctionnement ; et
h) les marquages.
1.2
Les toilettes visées par cette norme sont conçues pour être utilisées lorsque…