1.1 General
This Standard specifies requirements for
a) mortar for use in bedding, jointing, and bonding of masonry units; and
b) grout for use in filling core, cell, or cavity space in unit masonry construction.
Notes:
1) The term “unit masonry” refers to masonry construction using clay (shale), calcium silicate (sand-lime), or
concrete masonry units, with individual units not more than 200 mm…
Household and similar electrical appliances - Safety - Part 2-7: Particular requirements for washing...
Scope
This clause of Part 1 is replaced by the following.
This International Standard deals with the safety of electric washing machines for household and similar use, that are intended for washing clothes and textiles, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances.
This standard also deals with the safety of electric washing machines…
Consists of N290.0-11, General requirements for safety systems of nuclear power plants and N290.1-13...
N290.0-11 - General requirements for safety systems of nuclear power plants
Preface
This is the first edition of CSA N290.0, General requirements for safety systems of nuclear power plants. This Standard is one of a series of standards on reactor control systems, safety systems, and instrumentation for nuclear power plants.
Scope
1.1
This Standard covers the design, qualification,…
Performance of highmast luminaires for roadway lighting
Scope
1.1
This Standard specifies photometric performance requirements for highmast luminaires that are used for roadway applications.
1.2
The following light sources are addressed in this Standard:
a) clear HPS lamp;
b) clear metal halide lamp; and
c) LED.
Note: Future editions of this Standard might include other light sources.
1.3
This Standard applies to highmast…
Scope
1.1
This Standard describes the methods for determining the level of depressurization and solutions to mitigate risk arising from depressurization.
1.2
This Standard applies to all existing single-family dwelling units contained in detached, semi-detached, and row houses equipped with an exhaust device, which have
a) a combustion device within the house; or
b) an attached…
Plume scavenging in surgical, diagnostic, therapeutic, and aesthetic settings
Scope
1.1
This Standard applies to systems and equipment used to capture and evacuate plume. It applies to all settings where such systems and equipment are used, including, but not limited to, the following:
a) surgical facilities;
b) dental clinics;
c) medical offices;
d) veterinary facilities;
e) laboratories and other research and testing facilities;
f) cosmetic…
Scope
1.1
This Standard applies to rigid unplasticized poly (vinyl chloride)* boxes and fittings of the following types that are intended to be installed and used with rigid PVC conduit at a maximum working temperature of 75 °C in accordance with the rules of the Canadian Electrical Code, Part I:
a) junction boxes with an interior volume of 1640 mL+ or less that are intended to provide…
Non-destructive testing — Qualification and certification of NDT personnel (ISO 9712:2012, IDT)
1 Scope
This International Standard specifies requirements for principles for the qualification and certification of
personnel who perform industrial non-destructive testing (NDT).
NOTE 1 The term “industrial” implies the exclusion of applications in the field of medicine.
The system specified in this International Standard can also apply to other NDT methods or to new techniques
within an…
Scope
1.1
This Standard applies to manufactured wiring systems for installation in accessible areas in dry, nonhazardous locations in accordance with the Canadian Electrical Code, Part I.
1.2
This Standard applies to manufactured wiring systems having a maximum voltage rating of 600 V, and a maximum current rating of 30 A.
1.3
This Standard applies to powered table systems covered in…
Scope, purpose, and application
1.1 Scope
This Standard establishes criteria for an emergency and continuity management program, hereinafter referred to as "the program."
1.2 Purpose
1.2.1 General
This Standard provides the requirements to develop, implement, evaluate, maintain, and continuously improve an emergency and continuity management program for prevention and mitigation,…