Small-bore connectors for liquids and gases in healthcare applications — Part 3: Connectors for ente...
ISO 80369-3:2016 specifies the dimensions and requirements for the design and functional performance of small-bore connectors intended to be used for connections on enteral medical devices and accessories.
NOTE 1 Enteral medical devices include enteral feeding sets, enteral drainage sets, enteral syringes, and patient interface devices including access ports.
It does not specify the…
Health informatics — Information security management in health using ISO/IEC 27002
ISO 27799:2016 gives guidelines for organizational information security standards and information security management practices including the selection, implementation and management of controls taking into consideration the organization's information security risk environment(s).
It defines guidelines to support the interpretation and implementation in health informatics of ISO/IEC 27002…
Composite suspension insulators for overhead lines > 75 kV
1.1
This Standard applies to suspension and dead-end composite insulators used on ac overhead transmission lines with a nominal voltage greater than 75 kV and a frequency not greater than 100 Hz.
1.2
This Standard specifies
a)
insulator characteristics (mechanical, electrical, and dimensional) and prescribe the conditions under which these characteristics are to be verified;
b)
test…
1.1
This Standard covers the requirements for guy composite insulators used in guy wires on overhead distribution lines operating at nominal voltages up to and including 75 kV. Guy insulators insulate or isolate guy wires for corrosion protection, higher insulation levels, clearances for maintenance and normal operation, and safety for the public and workers (joint-use). Guy composite insulators…
1.1
This Standard applies to mechanical flue-gas exhausters intended to be installed in a flue pipe,
breeching, or chimney and serving appliances burning natural gas, propane, or fuel oil.
1.2
This Standard covers the mechanical and electrical features of mechanical flue-gas exhausters for indoor
or outdoor installations.
1.3
This Standard classifies mechanical flue-gas exhausters as:
a)…
Special use attachment plugs, receptacles, and connectors
1.1
This Standard applies to plugs, receptacles, power inlets and outlets, connectors, and similar wiring devices intended for use in electronic and electrical applications in accordance with the Canadian Electrical Code, Part I. The types covered are as follows (see Figure 3):
a)
Type 0 rated up to 8.3 A and up to 30 V rms (42 V peak);
b)
Type 1A rated up to 8.3 A and from 30 V to 600 V ac…
Reduction of fugitive and vented emissions for upstream petroleum and natural gas industry systems
1.1
This Standard specifies criteria to develop emission reduction practices and programs.
1.2
This Standard addresses fugitive and vented emissions from point sources in the following sectors (see
Figure 1) of the upstream oil and gas industry from wells, pipelines, and facilities associated with
a) crude oil production and shale oil;
b) oil sands – in situ bitumen production, including…
Systems for evacuation of plume generated by medical devices
1.1 This International Standard specifies requirements and guidelines for the design, manufacture,
installation, function, performance, maintenance, servicing, documentation, testing, and commissioning
of equipment for evacuation of plume generated by medical devices.
NOTE A plume evacuation system (PES) can be a functionally independent component of a medical device
that has other functions.
1.2…
Small-bore connectors for liquids and gases in healthcare applications -- Part 3: Connectors for ent...
ISO 80369-3:2016 specifies the dimensions and requirements for the design and functional performance of small-bore connectors intended to be used for connections on enteral medical devices and accessories. NOTE 1 Enteral medical devices include enteral feeding sets, enteral drainage sets, enteral syringes, and patient interface devices including access ports. It does not specify the dimensions…
1.1
This Standard applies to wet-process porcelain and toughened glass suspension-type insulators used on ac overhead power lines with a nominal voltage greater than 1000 V and a frequency not greater than 100 Hz.
This Standard applies to single insulator units only and does not apply to long rod insulators.
1.2
This Standard specifies provisions for
a)
the mechanical, electrical, and…