fireplaces and appliances intended to be vented through the throat of a masonry fireplace. These
appliances are designed for burning solid fuels such as wood and coal.
1.2 This Standard covers catalytic combustors utilized with fireplace inserts.
1.3 Fireplace inserts and hearth-mounted stoves as covered by this standard are not certified for
installation in factory-built fireplaces within…
NORME SUR LES FOYERS ENCASTRABLES ET LES POÊLES SUR SOCLE
1.1 La présente norme s’applique aux poêles sur socle et aux foyers encastrables préfabriqués pour les
foyers en maçonnerie et les appareils dans lesquels l’évacuation d’air se fait par la gorge du foyer en
maçonnerie. Ces appareils sont conçus pour brûler des combustibles solides comme du bois et du
charbon.
1.2 Cette norme porte sur les chambres de combustion catalytiques utilisées avec les…
1.1 These requirements apply to Factory-Built Type A Chimneys, which do not require field fabrication.
The chimneys are typically intended for use with gas and liquid fuel-fired residential appliances and
building heating equipment, where the appliance or equipment flue-gas temperatures do not exceed
540 °C.
1.2 The chimneys are typically intended for use in accordance with regulatory Codes,…
1.1 These requirements apply to factory-built chimney assemblies which do not require field fabrication.
1.2 The factory-built chimney assemblies are for use with gas, liquid and solid fuel-fired residential
appliances and building heating equipment, where the flue-gas temperatures normally do not exceed
650 ºC.
1.3 The factory-built chimney assemblies are intended for installation and use in…
1.1 These requirements cover the design and construction of Type L vents intended for the venting of
flue gases having temperatures not exceeding 300 °C, from fuel-burning appliances certified for use with
Type L vents. The vents may also be used where Type B gas vents are used. They are intended for
installation in buildings to provide a passageway for conveying flue gases to the outer air…
1.1 The requirements of this Standard cover the design and construction of Type B (round or oval) and
Type BW Gas Vents.
1.2 Type B Gas Vents are intended for the venting of flue gases having temperatures not exceeding
245 °C, from gas fired appliances certified with draft hoods or diverters. Type B Gas Vents are also
intended for use with gas fired appliances, without draft hoods or…
STANDARD FOR FACTORY-BUILT CHIMNEY CONNECTORS AND WALL PASS-THROUGH ASSEMBLIES
1.1 These requirements apply to factory-built chimney connectors and wall pass-through assemblies that
do not require field fabrication.
1.2 The factory-built chimney connectors and wall pass-through assemblies are for use with gas, liquid
and solid-fuel-fired residential appliances and building heating equipment where the flue-gas temperatures
do not normally exceed 650 °C.
1.3 Factory-…
1 Scope
1.1 This Standard applies to grounding and bonding equipment for use in accordance with CSA C22.1,
Canadian Electrical Code, Part I in Canada, the National Electrical Code, NFPA 70, in the United States,
or the Standard for Electrical Installations, NOM-001-SEDE, in Mexico.
1.2 This Standard applies to the following grounding and bonding equipment:
a) ground clamps, bonding devices,…
1 Scope
1.1 These fuseholders and devices accommodate fuses to be employed in electrical circuits and are
intended to be used in accordance with the Canadian Electrical Code, Part I (CE Code Part I), CSA C22.1,
the National Electrical Code, NFPA 70, or the Mexican Electrical Code, NOM-001.
1.2 These requirements cover:
a) Fuseholders for fuses intended for use with fuse classes covered in…
Household and similar electrical appliances — Safety — Part 2-69: Particular requirements for wet an...
1 Scope
This clause of Part 1 is replaced by the following.
This part of IEC 60335 deals with the safety of electrical motor-operated vacuum cleaners, including BACKPACK
VACUUM CLEANERS, and DUST EXTRACTORS, for wet suction, dry suction, or wet and dry suction,
intended for commercial indoor or outdoor use with or without attachments. They may be provided with a
blowing or inflating function…