1.1 Scope
1.1.1 This standard applies to newly produced gas food service equipment providing coverage for ranges and unit broilers, baking and roasting ovens, counter appliances, deep fat fryers, kettles, steam cookers, steam generators, (see Part IV, Definitions) hereinafter referred to as either (1) "appliances," constructed entirely of new, unused parts and materials for use in food…
Industrial automation systems and integration — Product data representation and exchange — Part 232:...
This part of ISO 10303 specifies the use of the integrated resources necessary for the scope and information requirements for Technical Data Packages (TDPs) (see 3.5.28) to be exchanged among product data management systems.
Each enterprise uses content, format, and the level of configuration control as parameters when establishing its product exchange or access requirements among business…
Medical Electrical Equipment - Part 2-23: Particular Requirements for the Safety, Including Essentia...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-23:1999, (second edition, 1999-12).
1 Scope and object
This clause of the General Standard applies except as follows:
*1.1 Scope
Addition:
This Particular Standard specifies requirements for the safety, including essential performance, of TRANSCUTANEOUS PARTIAL PRESSURE MONITORING EQUIPMENT, as defined in 2.…
Medical Electrical Equipment - Part 2-30: Particular Requirements for the Safety, Including Essentia...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-30:1999, (second edition, 1999-12).
Scope and object
This clause of the General Standard applies except as follows:
*1.1 Scope
Addition:
This Particular Standard specifies requirements for the safety, including essential performance, of AUTOMATIC CYCLING NON-INVASIVE BLOOD PRESSURE MONITORING EQUIPMENT as…
Personal fall-arrest systems — Part 4: Vertical rails and vertical lifelines incorporating a sliding...
This part of ISO 10333 specifies requirements, test methods, instructions for use and maintenance, marking, labelling and packaging, as appropriate, for vertical rails and vertical lifelines which incorporate a sliding-type fall arrester.
When connected to a full-body harness as specified in ISO 10333-1, vertical rails and vertical lifelines which incorporate a sliding-type fall arrester…
Plaques-couvercles pour dispositifs de câblage en affleurement
1 Domaine d'application
Norme binationale avec UL 514D
1.1 Cette norme vise les plaques-couvercles métalliques et non métalliques pour les dispositifs de câblage en affleurement, garnitures comprises, destinées à être installés conformément au National Electrical Code, NFPA 70, et au Code canadien de l'électricité, Première partie.
1.2 Cette norme vise également les capots de…
1 Scope
Bi-national standard, with UL 1565
1.1 This standard applies to those metallic and nonmetallic devices used for positioning - which may include bundling and securing - or to a limited extent supporting cable, wire, conduit, or tubing of a wiring system in electrical installations, to reduce the risk of fire, electric shock, or injury to persons. This standard applies to, but is not…
1.1 Scope
1.1.1
This standard applies to newly produced vented gas fireplace heaters (See Part IV, Definitions), hereinafter referred to as appliances, constructed entirely of new, unused parts and materials:
a. For use with natural gas;
b. For use with liquified petroleum (propane);
c. Direct vent appliances for manufactured home (USA only) or mobile home OEM…
Design and Construction of Building Components with Fibre-Reinforced Polymers
1 Scope
1.1 General
This Standard provides requirements for the design and evaluation of building components of fibre-reinforced polymers (FRP) in buildings and of building components reinforced with FRP materials. It is based on limit states design principles and is consistent with the National Building Code of Canada.
This Standard does not apply to the design of fibre-reinforced concrete (…
Moulded-Case Circuit Breakers, Molded-Case Switches and Circuit-Breaker Enclosures
1 Scope
1.1 The requirements of this standard cover molded-case circuit breakers, circuit breaker and ground-fault circuit-interrupters, fused circuit breakers, and accessory high-fault protectors. These circuit breakers are specifically
intended to provide service entrance, feeder, and branch circuit protection in accordance with the National Installation Codes in Appendix B, Ref. No.1.…