American National Standard/ CSA Standard For Gas-Fired Low Intensity Infrared Heaters
1.1 Scope
1.1.1
This standard applies to newly produced, gas-fired low-intensity infrared heaters and infrared radiant tube heaters (see Part IV, Definitions), hereinafter referred to as heaters or appliances, constructed entirely of new, unused parts and materials with inputs up to and including 400 000 Btu/hr (117.23 kW) per burner:
a. For use with natural gas;
b. For use with…
1.1 Scope
1.1.1
This standard applies to newly produced, direct gas-fired process air heaters of the recirculating or non-recirculating type, (See Definition), hereinafter referred to as heaters, whose primary purpose is to provide process heating to non-occupied spaces within commercial and industrial buildings and may also include operation as a non-recirculating ventilation air heater, (See…
ISO 17088:2008 specifies procedures and requirements for the identification and labelling of plastics, and products made from plastics, that are suitable for recovery through aerobic composting. The four following aspects are addressed:
biodegradation;
disintegration during composting;
negative effects on the composting process and facility;
negative effects on the quality of the resulting…
ISO 5489:2007 specifies requirements for a ship's embarkation ladder that is provided to enable safe embarkation of waterborne survival craft along a vertical portion of the ship's hull. It is applicable to merchant ships required to carry embarkation ladders under Chapter III of the 1974 International Convention for the Safety of Life at Sea (SOLAS), as amended. National maritime…
Energy performance of buildings — Calculation of energy use for space heating and cooling
ISO 13790:2008 gives calculation methods for assessment of the annual energy use for space heating and cooling of a residential or a non-residential building, or a part of it, referred to as “the building”.
This method includes the calculation of:
the heat transfer by transmission and ventilation of the building zone when heated or cooled to constant internal temperature…
Preface
This is the harmonized ANCE, CSA, and UL Standard for Thermoplastic-Insulated Wires and Cables. It is the fourth edition of NMX-J-010-ANCE, the ninth edition of CSA-C22.2 No. 75, and the fourteenth edition of UL 83. This edition of CSA-C22.2 No. 75 supersedes the previous edition published in 2003. This edition of UL 83 supersedes the previous edition published in 2003.
1 Scope
1.1…
Quality management - Customer satisfaction - Guidelines for dispute resolution external to organizat...
This National Standard of Canada is equivalent to International Standard ISO 10003:2007.
1 Scope
This International Standard provides guidance for an organization to plan, design, develop, operate, maintain
and improve an effective and efficient dispute-resolution process for complaints that have not been resolved
by the organization. This International Standard is applicable to:
-…
Conduits métalliques rigides en acier pour canalisations électriques
1 Domaine d'application
1.1
Cette norme s'applique aux conduits métalliques rigides en acier (ERMC-S) ainsi qu'à leurs coudes,
raccords et mamelons, destinés à la fabrication des canalisations métalliques pour fils et câbles
conformément à la CSA C22.1, Code canadien de l'électricité, Première partie, à la NOM-001-SEDE, Standard
for Electrical Installations et à la NFPA…
Medical Electrical Equipment - Part 1: General Requirements for Basic Safety and Essential Performan...
This National Standard of Canada is based on International Standard IEC 60601-1:2005.
1.1 * Scope
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS.
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME…
Medical Electrical Equipment - Part 2-2: Particular Requirements for the Safety of High Frequency Su...
This National Standard of Canada is equivalent to International Standard CEI/IEC 60601-2-2:2006.
1 Scope and object
This clause of the General Standard applies except as follows:
*1.1 Scope
Addition: