Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 2: Test methods
Gives the test methods specified in all parts of IEC 60245 as far as not laid down in IEC 60811, plus those in Amendment 1 (1997) (Flexing test) and Amendment 2 (1998) (Three pulley flexing test and kink test) This consolidated version consists of the second edition (1994), its amendment 1 (1997) and its amendment 2 (1997). Therefore, no need to order amendments in addition to this publication.
Optical fibre cables - Part 3: Duct, buried and aerial cables - Sectional specification
Specifies the requirements of single-mode optical fibre cables and cable elements which are intended to be used primarily in public telecommunications networks. Other types of applications requiring similar types of cables can be considered. Requirements for cables to be used in ducts or for directly buried application and aerial cables are covered in this standard.
Luminaires - Part 2: Particular requirements - Section Seventeen - Luminaires for stage lighting, te...
This National Standard of Canada is based on International Standards CEI/IEC 598-2-17:1984 (first edition, 1984), including Amendment 1:1997 and 2:2000.
17.1 Scope
This Standard specifies requirements for stage, television, film and photographic studio luminaires (including spot and floodlighting projectors) for use, outdoors and indoors, with tungsten filament, tubular fluorescent, and…
Ballasts for discharge lamps (excluding tubular fluorescent lamps) - General and safety requirements
This National Standard of Canada is based on International Standard IEC 922:1989, Including A1-1990 and A2-1992.
1. Scope
This standard specifies safety requirements for ballasts for discharge lamps such as high-pressure mercury vapour, low- pressure sodium vapour, high-pressure sodium vapour and metal halide lamps. Section One specifies general requirements and Section Two specifies…
Auxiliaries for lamps - A.C. supplied electronic ballasts for tubular fluorescent lamps - General an...
This National Standard of Canada is based on International Standard IEC 928:1995.
1. Scope
This standard specifies general and safety requirements for electronic ballasts for use on a.c. supplies up to 1000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply frequency, associated with tubular fluorescent lamps as specified in IEC 81 and other tubular fluorescent lamps for…
Luminaires - Part 2: Particular requirements - Section Five - Floodlights
Scope
This section of Part 2 of IEC Publication 598 specifies requirements for floodlights for use with tungsten filament, tubular fluorescent and other discharge lamps on supply voltages not exceeding 1 000 V. It is to be read in
conjunction with those sections of Part 1 to which reference is made.