Essais des câbles électriques et des câbles à fibres optiques soumis au feu - Partie 3-25: Essai de ...
L’IEC 60332-2-25:2018 couvre la catégorie D pour les méthodes d'essai pour l'évaluation de la propagation verticale de la flamme des fils ou câbles, électriques ou optiques, disposés en nappes en position verticale, dans des conditions définie. Le présent document ne concerne que les petits câbles de diamètre extérieur inférieur ou égal à 12 mm et de section inférieure ou égale à 35 mm2…
Tests on electric and optical fibre cables under fire conditions - Part 3-21: Test for vertical flam...
IEC 60332-3-21:2018 covers category A F/R for methods of test for the assessment of vertical flame spread of vertically-mounted bunched wires or cables, under defined conditions. This document relates only to power cables of conductor cross-sectional area greater than 35 mm2 installed on the test ladder in a spaced configuration on the front and rear to achieve a nominal total volume of non-…
Essais des câbles électriques et des câbles à fibres optiques soumis au feu - Partie 3-21: Essai de ...
L’IEC 60332-3-21:2018 couvre la catégorie A F/R pour les méthodes d'essai pour l'évaluation de la propagation verticale de la flamme des fils ou câbles, disposés en nappes en position verticale, dans des conditions définies. Le présent document concerne uniquement les câbles d'énergie ayant au moins un conducteur de section supérieure à 35 mm2 installés sur l'échelle d'…
Tests on electric and optical fibre cables under fire conditions - Part 3-22: Test for vertical flam...
IEC 60332-3-22:2018 covers category A for methods of test for the assessment of vertical flame spread of vertically mounted bunched wires or cables, electrical or optical, under defined conditions. This document relates to cables installed on the test ladder to achieve a nominal total volume of non-metallic material of 7 l/m of test sample. The flame application time is 40 min. The method of…
Essais des câbles électriques soumis au feu - Partie 3-22: Essai de propagation verticale de la flam...
L’IEC 60332-3-22:2018 couvre la catégorie A pour les méthodes d'essai pour l'évaluation de la propagation verticale de la flamme des fils ou câbles, électriques ou optiques, disposés en nappes en position verticale, dans des conditions définie. Le présent document concerne les câbles montés sur l'échelle d'essai afin d’obtenir un volume total nominal de matériau non métallique…
Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flam...
IEC 60332-3-10:2018 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 60332-3-10:2018 details the apparatus and its arrangement and calibration for methods of test for the…
Tests on electric and optical fibre cables under fire conditions - Part 3-24: Test for vertical flam...
IEC 60332-3-24:2018 covers category C for methods of test for the assessment of vertical flame spread of vertically mounted bunched wires or cables, electrical or optical, under defined conditions. This document relates to cables installed on the test ladder to achieve a nominal total volume of non-metallic material of 1,5 l/m of test sample. The flame application time is 20 min. The method of…
Essais des câbles électriques et des câbles à fibres optiques soumis au feu - Partie 3-24: Essai de ...
L’IEC 60332-3-24:2018 couvre la catégorie C pour les méthodes d'essai pour l'évaluation de la propagation verticale de la flamme des fils ou câbles électriques ou optiques, disposés en nappes en position verticale, dans des conditions définie. Le présent document concerne les câbles montés sur l'échelle d'essai afin d’obtenir un volume total nominal de matériau non métallique…
Tests on electric and optical fibre cables under fire conditions - Part 3-23: Test for vertical flam...
IEC 60332-3-23:2018 covers category B for methods of test for the assessment of vertical flame spread of vertically-mounted bunched wires or cables, electrical or optical, under defined conditions.
This document relates to cables installed on the test ladder to achieve a nominal total volume of non-metallic material of 3,5 l/m of test sample. The flame application time is 40 min. The method of…
Essais des câbles électriques et des câbles à fibres optiques soumis au feu - Partie 3-23: Essai de ...
L’IEC 60332-3-23:2018 couvre la catégorie B pour les méthodes d'essai pour l'évaluation de la propagation verticale de la flamme des fils ou câbles, électriques ou optiques, disposés en nappes en position verticale, dans des conditions définie. Le présent document concerne les câbles montés sur l'échelle d'essai afin d’obtenir un volume total nominal de matériau non métallique…