1 Scope
O437.0
1.1 This Standard pertains specifically to a class of mat-formed structural panelboards made predominantly of wood strands or wafers of a minimum and controlled length, a controlled thickness, and a variable or predetermined width, bonded together with a waterproof and boilproof binder.
1.2 These panelboards are intended, and used extensively, for construction applications…
Cinematography — Splices for use on 70 mm, 65 mm, 35 mm and 16 mm motion-picture films — Dimensions ...
Specifies dimensions and locations of transverse cemented or welded overlap splices and butt splices on one laboratory type and 4 projection types of film and print with magnetic or photographic sound records.
Toxicity testing of fire effluents — Part 5: Prediction of toxic effects of fire effluents
Reviews the progress of bioanalytical methodology, including the application of mathematical models which are available and may be used in the toxicological assessment of fire effluent atmospheres. Attention is also given to the application of such models as a means to minimize the use of laboratory animals in the testing of materials for fire effluent toxicity.
Test Method for Determining the Anaerobic Biodegradability of Plastic Materials
1.1
This Standard specifies the laboratory test method condition for determining
the anaerobic biodegradability of plastic materials on exposure to primary
anaerobic digestor sludge obtained from the treatment of primary clarifier
sludge at a municipal waste water treatment plant.
The degree and rate of anaerobic biodegradability of a plastic material in the
environment determines to what…
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-0...
Applies to the following hand-held and hand-manipulated probe assemblies: -low-voltage and high-voltage, non-attenuating probe assemblies (type A) -high-voltage attenuating or divider probe assemblies (type B) -low-voltage attenuating or divider probe assemblies (type C). Has the status of a group safety publication in accordance with IEC Guide 104.
Specifies requirements for the safety of capnometers and refers to and is applicable in conjunction with IEC 601-1 (Safety of medical electrical equipment, General safety requirements). Applies to capnometers used with adults, children and neonates. Does not apply to devices intended for use as transcutaneous monitors or intended for use in laboratory research applications.
Calibration and testing laboratory accreditation systems — General requirements for operation and re...
Sets out the general requirements for the operation of a system for accreditation of calibration and/or testing laboratories so that the accreditations granted and the services covered by the accreditations may be recognized at a national or an international level and the body operating the accreditation system may be recognized at national or international level as competent and reliable. The…