Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-10...
IEC 61010-2-101:2015 applies to equipment intended for in vitro diagnostic (IVD) medical purposes, including self-test IVD medical purposes. It has the status of a group safety function, as specified in IEC Guide 104. This standard has been prepared in close collaboration with Working Group CENELEC BTTF 88.1. This second edition cancels and replaces the first edition published in 2002. It…
Surface cleaning appliances - Part 3: Wet carpet cleaning appliances - Methods for measuring the per...
IEC 62885-3:2014 is applicable to wet cleaning appliances for household use for carpet cleaning in or under conditions similar to those in households. This part of IEC 62885 is not applicable to steam cleaning vacuums. The purpose of this standard is to:<br />
- specify the essential performance characteristics of wet cleaning appliances being of interest to users<br />
- describe…
Surface cleaning appliances - Part 3: Wet carpet cleaning appliances - Methods for measuring the per...
IEC 62885-3:2014 is applicable to wet cleaning appliances for household use for carpet cleaning in or under conditions similar to those in households. This part of IEC 62885 is not applicable to steam cleaning vacuums. The purpose of this standard is to:
- specify the essential performance characteristics of wet cleaning appliances being of interest to users
- describe methods for measuring…
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
1 Scope and object
This clause of Part 1 is applicable, except as follows:
1.1.1 Equipment included in scope
Replacement:
Replace the text with the following:
This part of IEC 61010 specifies particular safety requirements for CABINET X-RAY SYSTEMS.
A CABINET X-RAY SYSTEM is a system that contains an X-ray tube installed in a cabinet which,
independently of existing architectural…
Optical fibre cables - Part 4-10: Family specification - Optical ground wires (OPGW) along electrica...
IEC 60794-4-10:2014 which is a family specification, covers cable construction, test methods and optical, mechanical, environmental and electrical performance requirements for OPGW (optical ground wire) which is used for the protection of electrical power lines against atmospheric discharges or short-circuits and, at the same time, as a high bandwidth transport media for communications-and-…
Optical fibre cables - Part 4-10: Family specification - Optical ground wires (OPGW) along electrica...
IEC 60794-4-10:2014 which is a family specification, covers cable construction, test methods and optical, mechanical, environmental and electrical performance requirements for OPGW (optical ground wire) which is used for the protection of electrical power lines against atmospheric discharges or short-circuits and, at the same time, as a high bandwidth transport media for communications-and-…
Live working - Protective clothing against the thermal hazards of an electric arc - Part 1-2: Test m...
IEC 61482-1-2:2014 specifies procedures to test material and garments intended for use in heat and flame-resistant clothing for workers if there is an electric arc hazard. A directed and constrained electric arc in a test circuit is used to classify material and clothing in two defined arc protection classes. This International Standard is not dedicated toward measuring the arc rating values (…
Electroacoustics - Octave-band and fractional-octave-band filters - Part 1: Specifications
IEC 61260-1:2014 specifies performance requirements for analogue, sampled-data, and digital implementations of band-pass filters. The extent of the pass-band region of a filter's relative attenuation characteristic is a constant percentage of the exact mid-band frequency for all filters of a given bandwidth. An instrument conforming to the requirements of this standard may contain any number…
Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test m...
IEC 60695-2-11:2014 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 60695-2-11:2014 specifies a test method on an end product. It is intended to simulate the effects of thermal…
Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test m...
IEC 60695-2-11:2014 specifies a test method on an end product. It is intended to simulate the effects of thermal stresses produced by an electrically heated source to represent a fire hazard. This test method is used to check that, under defined test conditions, an end product exposed to an electrically heated source has either a limited ability to ignite or, if it ignites, a limited ability to…