Test methods for repair materials for water-leakage cracks in underground concrete structures — Part...
ISO/TS 16774-5:2017 specifies a laboratory test method for evaluating watertightness of water-leakage crack repair materials through permeability testing.
These permeability test procedures follow applied conditions outlined in different national testing parameters and requirements. As such, the results are only intended to provide a comparative performance evaluation of the waterproofing repair…
Test methods for repair materials for water-leakage cracks in underground concrete structures — Part...
ISO/TS 16774-6:2017 specifies a laboratory test method for evaluating the substrate (crack) movement response of water-leakage crack repair materials through permeability testing.
The repair material injected into a test specimen with an artificial crack undergoes simulated movements normally caused by thermal expansion, settlement and vibrations in leakage cracks found in concrete structures…
Methods for the calibration of vibration and shock transducers — Part 45: In-situ calibration of tra...
ISO 16063-45:2017 specifies the calibration of vibration transducers with built-in calibration coils in laboratory and in situ. In laboratory, the method described can be applied to calibrate the vibration sensitivity and electrical sensitivity, and to obtain the coefficient of calibration coil. In situ, it can be used to calibrate the electrical sensitivity and vibration sensitivity using…
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-1: Immu...
IEC 61326-3-1:2017 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 61326-3-1:2017 covers all equipment within the scope of IEC 61326-1, but is limited to systems and equipment…
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immu...
IEC 61326-3-2:2017 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 61326-3-2:2017 covers all equipment within the scope of IEC 61326-1, but is limited to systems and equipment…
Electrical equipment for measurement, control and laboratory use - EMC requirements – Part 3-1: Immu...
IEC 61326-3-1:2017 covers all equipment within the scope of IEC 61326-1, but is limited to systems and equipment for industrial applications intended to perform safety functions as defined in IEC 61508 with SIL 1-3.
This second edition cancels and replaces the first edition published in 2008. This edition constitutes a technical revision. This edition includes the following significant technical…
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immu...
IEC 61326-3-2:2017 covers all equipment within the scope of IEC 61326-1, but is limited to systems and equipment for industrial applications within a specified electromagnetic environment and intended to perform safety functions as defined in IEC 61508 with SIL 1-3.
This second edition cancels and replaces the first edition published in 2008. This edition constitutes a technical revision. This…
Implants for surgery — Orthopaedic joint prosthesis — Part 1: Procedure for producing parametric 3D ...
ISO 19233-1:2017 provides requirements for capturing necessary bone geometries, when using a medical X-ray computed tomography apparatus, to provide the information for applications such as preoperative planning, surgical navigation, robotic surgeries, patient matched instruments and personalized total knee joint prosthesis. The conditions to scan images of bones and the conditions to reconstruct…
Dentistry — Laboratory cutters — Part 3: Carbide cutters for milling machines
ISO 7787-3:2017 specifies dimensional and other requirements for the three most commonly used carbide cutters for milling machines which are predominantly used in the dental laboratory.
Other characteristics of laboratory cutters (for example, spiralled blades or cross-cut) are not covered by this document.
Cutters intended for use with CAD/CAM systems are excluded from the scope of this document.
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
1.1.1 Scope
Replacement:
This Part 2 is applicable to electrically powered LABORATORY CENTRIFUGES.
This group safety publication is primarily intended to be used as a product safety standard for
the products mentioned in the scope, but shall also be used by technical committees in the
preparation of its publications for products similar to those mentioned in the scope of this
standard, in…