Corrosion of metals and alloys — Corrosion and fouling in industrial cooling water systems — Part 2:...
This document specifies the principles, reagents and materials, test apparatus, test methods, evaluation of results and requirements for test reports using pilot tests for industrial cooling water systems.
This document specifies a method to evaluate the performance of treatment programmes for open recirculating cooling water systems. It is based primarily on laboratory testing, but the heat…
Plastics — Methods of exposure to laboratory light sources — Part 4: Open-flame carbon-arc lamps
This document specifies methods for exposing specimens to open-flame carbon-arc lamps in the presence of moisture to reproduce the weathering effects that occur when materials are exposed in actual end-use environments to global solar radiation, or to window-glass filtered solar radiation.
The specimens are exposed to filtered open-flame carbon-arc light under controlled environmental conditions…
Plastics — Marine biodegradation testing — Preparation of optimized intertidal seawater and sediment
This document specifies procedures for preparing seawater and sediments used in test methods to assess the biodegradation of plastic materials in the marine environment. The screened sediment and sediment-rinsed seawater are prepared to sustain aerobic testing at laboratory scale. The described method is designed to separate sediment-rinsed seawater and sand-gravel sediments from intertidal…
Medical laboratories — Concepts and specifications for the design, development, implementation and u...
This document establishes requirements for assuring quality, safety, performance and documentation of laboratory-developed tests (LDTs) as per their intended use for the diagnosis, prognosis, monitoring, prevention or treatment of medical conditions.
It outlines the general principles and assessment criteria by which an LDT shall be designed, developed, characterized, manufactured, validated (…
Household and similar electrical appliances - Safety - Part 2-34: Particular requirements for motor-...
IEC 60335-2-34:2024 EXV contains both the international standard and its extended version (EXV). This extended version of the official IEC Standard is available in English only and provides the user with a comprehensive content of the Standard. IEC 60335-2-34:2024 EXV includes the content of the references made to IEC 60335-1:2020.
IEC 60335-2-34:2024 deals with the safety of sealed (hermetic…
Household and similar electrical appliances - Safety - Part 2-34: Particular requirements for motor-...
This pack contains IEC 60335-2-34:2024 EXV and IEC 60355-2-34:2024 CMV.
IEC 60335-2-34:2024 deals with the safety of sealed (hermetic and semi-hermetic type) motor-compressors, their protection and control systems, if any, which are intended for use in equipment for household and similar purposes and which conform with the standards applicable to such equipment. It applies to motor-compressors…
Household and similar electrical appliances - Safety - Part 2-34: Particular requirements for motor-...
IEC 60335-2-34:2024 CMV contains both the official standard and its commented version. The commented version provides you with a quick and easy way to compare all the changes between IEC 60335-2-34:2024 edition 7.0 and the previous IEC 60335-2-34:2021 edition 6.0. Furthermore, comments from IEC SC 61C experts are provided to explain the reasons of the most relevant changes, or to clarify any part…
Household and similar electrical appliances - Safety - Part 2-34: Particular requirements for motor-...
IEC 60335-2-34:2024 deals with the safety of sealed (hermetic and semi-hermetic type) motor-compressors, their protection and control systems, if any, which are intended for use in equipment for household and similar purposes and which conform with the standards applicable to such equipment. It applies to motor-compressors tested separately, under the most severe conditions that can be expected…
In vitro diagnostic medical devices — Multiplex molecular testing for nucleic acids — Part 3: Interp...
This document gives the general requirements for interpretation and reporting of multiplex molecular tests which simultaneously identify two or more nucleic acid target sequences of interest. This document is applicable to all multiplex methods used for examination using in vitro diagnostic (IVD) medical devices and laboratory developed tests (LDTs). It provides information for both qualitative…
Mechanical vibration — Laboratory method for evaluating vehicle seat vibration — Part 3: Specificati...
This document specifies dynamic dummies used as replacements for participants in vibration tests of vehicle seats in laboratory.
This document is applicable to seats installed in earth-moving machinery, agricultural wheeled tractors, and industrial trucks.
This document specifies technical requirements, acceptance criteria, and a validation test for dynamic dummies representing the human body in…