Measurement microphones - Part 3: Primary method for free-field calibration of laboratory standard m...
Applies to laboratory standard microphones meeting the requirements of IEC 61094-1. The principles of the method are applicable to other types of microphones. In particular, microphones which fulfil the requirements of IEC 61094-1, when fitted with a special adaptor, may also be calibrated according to this standard when the adaptor is removed.
Specifies a primary method of determining the free-…
States a laboratory test procedure to evaluate the axial (lateral) kerb impact collision properties of a wheel manufactured either wholly or partly of light alloys. It is intended for passenger car applications, with the purpose of screening and/or quality control of the wheel.
Earth-moving machinery — Laboratory evaluations of protective structures — Specifications for deflec...
Specifies the deflection-limiting volume (DLV) to be used when performing laboratory evaluations of protective structures which provide protection to operators of earth-moving machinery.
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-0...
Applies to electrically powered laboratory atomic spectrometers with thermal atomization, including atomic absorption spectrometers, emission flame photometers, atomic fluorescence spectrophotometers, inductively coupled plasma spectrometers, microwave coupled plasma spectrometers, and mass spectrometers, all with thermal atomization and ionization (including tubing and connectors which are…
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-0...
Applies to electrically operated laboratory equipment and its accessories for mechanical mixing and stirring, where mechanical energy influences the shape or size or homogeneity of materials and their accessories. The requirements for equipment which contain heating devices are given in IEC 61010-2-010. This publication has the status of a group safety publication in accordance with IEC Guide 104.
Specifies requirements for test sieves for the laboratory determination of foreign matter in a sample of cereals. Does not apply to test sieves for testing cereals for insect infestation. Cancels and replaces the second edition, which has been technically revised.
Acoustics — Measurement of insertion loss of ducted silencers without flow — Laboratory survey metho...
Specifies a laboratory substitution method to determine the insertion loss of ducted circular and rectangular silencers without flow, as well as other duct elements for use in ventilating and air-conditioning systems.
Methods of Sampling and Testing Waxes and Polishes
Slip Resistance
1. Scope
1.1 This test method covers the measurement of the static coefficient of
friction of floor surfaces for the James Machine. The apparatus is not
suitable for use on wet, rough, or corrugated surfaces. The apparatus is
suitable for laboratory testing.
1.2 This standard does not purport to address all of the safety problems, if
any, associated with its use. It is the…
1. Scope
1.1 This method of test is applicable to firestop systems incorporating through
penetrations or poke-through termination devices as well as to firestops alone
(material with no penetrations). These firestop systems are intended for use
in openings in wall and floor assemblies required to have a fire resistance
rating as established in CAN/ULC-S101M, Standard Methods of Fire…