Cereals and cereal products — Determination of 17 mycotoxins by ultra-high-performance liquid chroma...
This document specifies a method for the quantitative determination of17 mycotoxins including aflatoxin B1, aflatoxin B2, aflatoxin G1, aflatoxin G2, deoxynivalenol, nivalenol, deoxynivalenol-3- Glucoside, 3-acetyl-deoxynivalenol, 15-acetyl-deoxynivalenol,zearalenone,ochratoxin A, fumonisinB1, fumonisinB2, fumonisinB3,T-2 toxin, HT-2 toxin, and sterigmatocystin in cereals and cereal products…
Fine-cut tobacco and smoking articles made from it — Methods of sampling, conditioning and analysis ...
This document specifies methods for the determination of total particulate matter and preparation for the subsequent determination of nicotine-free dry particulate matter present in the smoke from articles made from fine-cut tobacco and expanded tobacco, generated and collected using a routine analytical smoking machine.
It specifies the method of making of fine-cut tobacco smoking articles using…
Appareils électromédicaux — Partie 2-69: Exigences particulières pour la sécurité de base et les per...
Le présent document spécifie les exigences applicables à la sécurité de base et aux performances essentielles d'un concentrateur d'oxygène en combinaison avec ses accessoires, désigné ci-après sous le terme d'appareil EM, visant à augmenter la concentration en oxygène du gaz destiné à être délivré à un patient unique. De tels concentrateurs d'oxygène sont, en général, destinés…
This document specifies the ICT perspective requirements to manage the information of response resources for a public health emergency (PHE) response. The scope of the document includes:
overview of response resource information management;
requirements for managing response resource information including:
information collection for monitoring the status of response resources;
information…
Matrices solides environnementales — Détermination de la conductivité électrique spécifique
La présente Norme internationale prescrit une méthode instrumentale pour la détermination en routine de la conductivité électrique spécifique d'un extrait aqueux de sol. La détermination est effectuée afin d'obtenir une indication sur la teneur en électrolytes hydrosolubles dans un échantillon de sol. La présente Norme internationale est applicable à tout échantillon de sol séché à l…
Determination and use of straight-line calibration functions
ISO/TS 28037:2010 is concerned with linear, that is, straight-line, calibration functions that describe the relationship between two variables X and Y, namely, functions of the form Y = A + BX. Although many of the principles apply to more general types of calibration function, the approaches described exploit the simple form of the straight-line calibration function wherever possible.
Values of…