Strength Design in Aluminum/Commentary on CSA S157-05, Strength Design in Aluminum
1 Scope
1.1
This Standard applies to the design of aluminum alloy members and assemblies intended to carry a known load.
1.2
This Standard specifies requirements for the design of members to meet the requirements of the National Building Code of Canada using limit states design procedures.
1.3
This Standard contains rules to determine the ultimate resistance of aluminum members and connections…
1 Scope
1.1 This Standard covers material, manufacturing, and class dimensional requirements for seasoned wood poles and reinforcing stubs that are primarily intended for the support of electrical power or communication lines.
1.2 This Standard does not cover requirements for wood poles intended for use in structures such as bridges and buildings.
1.3 This Standard does not cover requirements…
1 Scope
1.1 Purpose
The purpose of this Standard is to minimize the risk of personal injury by providing minimum requirements for the design, construction, installation, inspection, and maintenance of the mechanical refrigeration systems specified in Clauses 1.2.1 and 1.2.2.
Note: This Standard does not directly address protection of property and preservation of the environment.
1.2…
The SFM Essentials: An Introduction to CAN/CSA-Z809-02, Sustainable Forest Management: Requirements ...
About This Handbook
The objective of this handbook is to provide forest managers and forest management practitioners with a user-friendly guide with information and ideas to assist in implementing the requirements found in Canada.s national sustainable forest management (SFM) Standard, CAN/CSA-Z809, Sustainable Forest Management: Requirements and Guidance.
This handbook includes all of the…
Scope
1.1.1 This Standard covers CGA 791 (Type I) and CGA 810 (Type II) cylinder connection devices, as defined in Part IV, Definitions, intended to connect the cylinder valve on portable LP-Gas containers to the inlet of the regulator on outdoor cooking gas appliances. These cylinder connection devices are intended for vapour withdrawal service only.
1.1.2 The cylinder connection devices…
Industrial Protective Headwear - Performance, Selection, Care, and Use
1 Scope
1.1
This Standard applies to protective headwear for industrial, construction, mining, utility, and forestry workers. It defines the areas of the head that are to be protected and includes basic performance requirements for dielectric strength, impact attenuation, penetration resistance, passive retention (stability), and shell flammability and liner ignition resistance.
1.2
This…
1 Scope
1.1 General
This Standard specifies requirements for the performance, design, testing, marking, and instructions of energy absorbers and lanyards, including lineman's pole straps and integrally connected lanyards and energy absorbers.
1.2 Applications
Energy absorbers and lanyards are used as parts of complete fall arrest, travel restraint, fall restrict, or work positioning…
Body Belts and Saddles for Work Positioning and Travel Restraint
1 Scope
1.1
This Standard specifies requirements for the performance, design, testing, marking, and instructions of body belts and saddles. Body belts and saddles are used as part of work positioning and travel restraint systems. 1.2 This Standard covers equipment such as
(a) lineman.s body belts;
(b) body belts;
(c) miners. belts; and
(d) arborists. saddles.
1.3
This Standard does…
Management System Requirements for Nuclear Power Plants
1 Scope
1.1 This Standard applies to the organization with overall responsibility for a nuclear power plant(s). This Standard also applies to other organizations, as designated by the organization with overall responsibility, which carry out activities during the life cycle of a nuclear power plant.
1.2 This Standard identifies management system requirements for design, purchasing, construction…
1 Scope
1.1
This Standard specifies requirements for Type NS75 and NS90 neutral supported cables for use on outdoor overhead electrical systems that have nominal voltages of 600 V or less for installation in accordance with the Canadian Electrical Code, Part I.
1.2
Neutral supported cables covered by this Standard consist of up to five conductors (one, two, or three insulated phase…