Information technology — Guidelines for slap tenprint fingerprintture
This document provides guidelines to follow during the acquisition process of slap tenprints in order to obtain fingerprints of the best quality possible within acceptable time constraints.
Non-cooperative users are out of the scope of this document.
When using ten-fingerprint sensors, it is fundamental to know how to use them and how to proceed with the acquisition. This document describes how…
Human resource management — Quality of hire metric
This document provides a range of options to measure the quality of hire that can be aligned to various business and organizational conditions. The QoH structure includes:
— purpose;
— formula;
— definition;
— how to use the metric:
— intended users;
— contextual factors for interpretation.
This document excludes measuring the "Impact of Hire"…
Systems interface between customer energy management system and the power management system - Part 1...
IEC 62746-10-3:2018 defines and describes methods and example XML artefacts that can be used to build a conformant adapter to enable interoperation between a utility distributed automation or demand response (DR) system based on the IEC common information model (CIM) and a utility smart grid user interface (SGUI) bridge standard (e.g., IEC 62746-10-1) to a customer facility. The scope is…
1.1 General
This Standard provides criteria for the design of blast-resistant window anchor systems for use in new or existing buildings.
1.2 Window types considered
1.2.1 General
The design criteria included in this Standard are intended for anchoring windows with glass types specified in Clause 1.2.2 and frame types specified in Clause 1.2.3, anchored on substrates specified in Clause 1.2.3…
Energy performance and capacity of household refrigerators, refrigerator-freezers,freezers, and misc...
1.1
This Standard applies to compact and household refrigerators, refrigerator-freezers, freezers, and miscellaneous refrigeration products that are electrically operated on a 60 Hz alternating current, with a nominal supply voltage of 115 V.
1.2
This Standard applies to
a)
refrigerators and refrigerator-freezers (Clause 8) with a maximum capacity of 1105 L (39 ft3);
b)
freezers (Clause 9…
Ferrite cores - Guidelines on dimensions and the limits of surface irregularities - Part 5: EP-cores...
IEC 63093-5:2018(E) specifies the dimensions that are of importance for mechanical interchangeability for a preferred range of EP-cores made of ferrite, the essential dimensions of coil formers to be used with them and the locations of their terminal pins on a 2,50 mm printed wiring grid in relation to the base outlines of the cores and the effective parameter values to be used in calculations…
Ferrite cores - Guidelines on dimensions and the limits of surface irregularities - Part 6: ETD-core...
IEC 63093-6:2018(E) specifies the dimensions that are of importance for mechanical interchangeability for a preferred range of ETD-cores made of ferrite and the essential dimensions of coil formers to be used with them, as well the effective parameter values to be used in calculations involving them. It also gives guidelines on allowable limits of surface irregularities applicable to ETD-cores.…
Ferrite cores - Guidelines on dimensions and the limits of surface irregularities - Part 5: EP-cores...
IEC 63093-5:2018 specifies the dimensions that are of importance for mechanical interchangeability for a preferred range of EP-cores made of ferrite, the essential dimensions of coil formers to be used with them and the locations of their terminal pins on a 2,50 mm printed wiring grid in relation to the base outlines of the cores and the effective parameter values to be used in calculations…
Ferrite cores - Guidelines on dimensions and the limits of surface irregularities - Part 6: ETD-core...
IEC 63093-6:2018 specifies the dimensions that are of importance for mechanical interchangeability for a preferred range of ETD-cores made of ferrite and the essential dimensions of coil formers to be used with them, as well the effective parameter values to be used in calculations involving them. It also gives guidelines on allowable limits of surface irregularities applicable to ETD-cores.
The…
Water reuse in urban areas — Guidelines for water reuse safety evaluation — Assessment parameters an...
This document provides water reuse safety evaluation and public acceptance parameters and methods for users who design, manage, and/or oversee the non-potable water reuse schemes or activities in urban areas from the viewpoint of water quality. The document can be used in various stages of non-potable water reuse projects such as design, operation, and post assessment.
The document is applicable…