Environmental monitoring programs at Class I nuclear facilities and uranium mines and mills
Scope
1.1 Facilities
1.1.1 Types of facilities
1.1.1.1
This Standard addresses the design and operation of EMPs for Class I nuclear facilities and uranium mines and mills. These facilities include
(a) nuclear reactors;
(b) uranium mines, mills, refineries, and conversion plants;
(c) uranium fuel fabrication plants;
(d) isotope-processing facilities;
(e) particle accelerators; and…
Chain of Custody of Forest-Based Products – Certification Protocol
1 PURPOSE
The purpose of this protocol is intended to establish certification program requirements for the
chain of custody of forest-based products according to the requirements of either the SFI or PEFC
chain of custody standards.
Certification of the chain of custody of forest-based products according to these standards will then
allow access to a labelling system for targeted SFM…
Heating cables with a rated voltage of 300/500 V for comfort heating and prevention of ice formation
IEC 60800:2009 is applicable to, and specifies requirements for, resistive heating cables for low temperature applications such as comfort heating and the prevention of ice formation. These cables and cable sets may comprise either factory fabricated or field (work-site) assembled units, and which are heating cables assembled in accordance with manufacturer's instructions. Bare conductors…
Wind turbines - Part 3: Design requirements for offshore wind turbines
IEC 61400-3:2009 specifies additional requirements for assessment of the external conditions at an offshore wind turbine site and specifies essential design requirements to ensure the engineering integrity of offshore wind turbines. Its purpose is to provide an appropriate level of protection against damage from all hazards during the planned lifetime. Focuses on the engineering integrity of the…
High-voltage switchgear and controlgear - Part 303: Use and handling of sulphur hexafluoride (SF<...
IEC/TR 62271-303:2008 addresses the procedures for safe and environmental compatible handling of SF6 during installation, commissioning, normal and abnormal operations, disposal at the end of life of high voltage switchgear and controlgear. Storage and transportation of SF6 are also covered. These procedures should be regarded as minimum requirements to ensure the safety of personnel working with…
Vapour Control Systems In Gasoline Distribution Networks
1. SCOPE
1.1 This standard defines equipment requirements, performance criteria, and operating and testing procedures for the implementation of a vapour control system (VCS) in gasoline distribution networks including terminals, bulk plants, service stations and cargo tanks, commonly known as Stage I. (See Figure 1 for a schematic representation.)
1.1.1 This standard does not include vapour…
Petroleum and Natural Gas Industries - Specific Requirements for Offshore Structures - Part 2: Seism...
This National Standard of Canada is based on International Standard ISO 19901-2:2004.
1 Scope
This part of ISO 19901 contains requirements for defining the seismic design procedures and criteria for offshore structures; guidance on the requirements is included in Annex A. The requirements are applicable to fixed steel structures and fixed concrete structures. The effects of seismic events…
Commercial building telecommunications cabling standard — Part 1: General requirements
CSA Preface
This is the first edition of CSA T568.1, Commercial building telecommunications cabling standard - Part 1: General requirements.
It replaces CSA T529-95, Telecommunications Cabling Systems in Commercial Buildings.
This Standard is an adoption of the identically titled ANSI/TIA/EIA (American National Standards Institute/Telecommunications Industry Association/Electronic…
Petroleum and natural gas industries — Specific requirements for offshore structures — Part 2: Seism...
ISO 19901-2:2004 contains requirements for defining the seismic design procedures and criteria for offshore structures; guidance on the requirements is included. The requirements are applicable to fixed steel structures and fixed concrete structures. The effects of seismic events on floating structures and partially buoyant structures are also briefly discussed. The site-specific assessment of…
Z241.0-03 Definitions and General Safety Requirements for Park Model Trailers
1. Scope This Standard provides the definition of the term "park model trailer" as used in the CSA Z241 Series. It also gives general safety requirements that apply to the other Standards in this Series.
Z241.1-03 Vehicular Requirements for Park Model Trailers
1. Scope
1.1 Requirement Specification…