Plastics piping systems for the supply of gaseous fuels — Polyethylene (PE) — Part 5: Fitness for pu...
This document specifies the requirements of fitness for purpose of assembled polyethylene (PE) piping systems in the field of the supply of gaseous fuels.
It specifies the requirements for electrofusion, socket fusion, butt fusion and mechanical joints.
It specifies the method of preparation of test piece joints and the tests to be carried out on these joints for assessing the fitness for purpose…
Pipes and joints made of oriented unplasticized poly(vinyl chloride) (PVC-O) for the conveyance of w...
This document specifies the characteristics of the fitness for purpose of oriented unplasticized poly(vinyl chloride) (PVC-O) solid wall piping intended to be used underground or above-ground where protected from direct sunlight, for water supply, buried drainage, sewerage, treated wastewater and irrigation under pressure. It also specifies the test parameters for the test methods referred to in…
Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies f...
IEC 61439-4:2023 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 61439-4:2023 defines the specific requirements of ACS as follows:
- assemblies for which the rated voltage does…
Power installations exceeding 1 kV AC and 1,5 kV DC - Part 2: DC
IEC 61936-2:2023 provides, in a convenient form, requirements for the design and the erection of DC installations in systems with nominal voltages above 1,5 kV DC, so as to provide safety and proper functioning for the use intended.
For the purpose of interpreting this document, a DC installation is considered to be one of the following:
a) A converter station or DC switching station;
b) one (…
Space systems — Interface control documents between ground systems, ground support equipment and lau...
This document establishes basic requirements for interface control documents (ICD) writing and interface control procedures for the following items included in the launch system: payload, launch vehicle, ground support equipment (according to ISO 14625) and launch site (buildings with utility systems), specifically:
a) ICD between the ground support equipment and the payload;
b) ICD…
Communication networks and systems for power utility automation - Part 90-7: Object models for power...
IEC TR 61850-90-7:2023 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC TR 61850-90-7:2023, which is a Technical Report, describes functions for power converter-based distributed…
Communication networks and systems for power utility automation - Part 90-7: Object models for power...
IEC TR 61850-90-7:2023, which is a Technical Report, describes functions for power converter-based distributed energy resources (DER) systems, focused on DC-to-AC and AC-to-AC conversions and including photovoltaic systems (PV), battery storage systems, electric vehicle (EV) charging systems, and any other DER systems with a controllable power converter. The functions defined in this document…
Measurement of radioactivity in the environment — Soil — Part 3: Test method of gamma-emitting radio...
This document specifies the identification and the measurement of the activity in soils of a large number of gamma-emitting radionuclides using gamma spectrometry. This non-destructive method, applicable to large-volume samples (up to about 3 l), covers the determination in a single measurement of all the γ-emitters present for which the photon energy is between 5 keV and 3 MeV.
Generic test…
Medical electrical equipment — Part 2-1: Particular requirements for the basic safety and essential ...
Scope
Replacement:
This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of ELECTRON
ACCELERATORS, hereafter referred to as ME EQUIPMENT, in the range 1 MeV to 50 MeV, used for
TREATMENT of PATIENTS.
NOTE 1 While ELECTRON ACCELERATORS used for TREATMENT of PATIENTS are always ME EQUIPMENT, there are times
in this document where they are referred to as EXTERNAL BEAM…
Live Working – Minimum Approach Distances – Part 2: Method of Determination of the Electrical Compon...
Scope
This part of IEC 61472 specifies a method for determining the electrical component of the minimum
approach distances for live working, for AC systems 1 kV up to and including 72,5 kV. This document
addresses system overvoltages and the working air distances between equipment and/or workers at
different potentials.
The withstand voltage and minimum approach distances determined by the…