Rechercher

Affiner les résultats
Code de la Classification internationale pour les normes (ICS)
Source
Code de l’organisme d’élaboration de normes (OEN)
Langue
Statut
Code de la Norme nationale du Canada (NNC)
Date de publication

De

à

Affichage 101 - 110 de 225
Safety requirements for electrical equipment for measurement, control and laboratory use – Part 2-08...
IEC 61010-2-081:2015 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition. IEC 61010-2-081:2015 applies to automatic and semi-automatic laboratory equipment for analysis and other purposes.…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2015-01-22
Code(s) de l'ICS :
19.080; 71.040.10
Safety requirements for electrical equipment for measurement, control and laboratory use – Part 2-10...
IEC 61010-2-101:2015 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition. IEC 61010-2-101:2015 applies to equipment intended for in vitro diagnostic (IVD) medical purposes, including self-…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2015-01-22
Code(s) de l'ICS :
11.040.55; 19.080
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-08...
IEC 61010-2-081:2015 applies to automatic and semi-automatic laboratory equipment for analysis and other purposes. Automatic and semi-automatic laboratory equipment consists of instruments or systems for measuring or modifying one or more characteristics or parameters of samples, performing the complete process or parts of the process without manual intervention. Equipment forming part of such a…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2015-01-22
Code(s) de l'ICS :
19.080; 71.040.10
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-10...
IEC 61010-2-101:2015 applies to equipment intended for in vitro diagnostic (IVD) medical purposes, including self-test IVD medical purposes. It has the status of a group safety function, as specified in IEC Guide 104. This standard has been prepared in close collaboration with Working Group CENELEC BTTF 88.1. This second edition cancels and replaces the first edition published in 2002. It…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2015-01-22
Code(s) de l'ICS :
11.040.55; 19.080
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-01...
IEC 61010-2-010:2014 specifies safety requirements for electrically powered laboratory equipment for the heating of materials, where the heating of materials is one of the functions of the equipment. This third edition cancels and replaces the second edition published in 2003. It constitutes a technical revision and includes the following significant changes from the second edition, as well as…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2014-09-24
Code(s) de l'ICS :
19.080; 71.040.20
Geographic information — Calibration and validation of remote sensing imagery sensors and data — Par...
ISO/TS 19159-1:2014 defines the calibration and validation of airborne and spaceborne remote sensing imagery sensors. The term "calibration" refers to geometry, radiometry, and spectral, and includes the instrument calibration in a laboratory as well as in situ calibration methods. The validation methods address validation of the calibration information.
Éditeur :
ISO
Statut :
Publié
Date de publication :
2014-07-10
Code(s) de l'ICS :
35.240.70
Water quality — Determination of dissolved oxygen — Optical sensor method
ISO 17289:2014 specifies an optical method for the determination of dissolved oxygen in water using a sensor working on the basis of fluorescence quenching. Measurement can be made either as a concentration of oxygen in milligrams per litre, percentage saturation (% dissolved oxygen), or both. Depending on the instrument used, detection limits of 0,1 mg/l or 0,2 mg/l can be reached according to…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2014-06-29
Code(s) de l'ICS :
13.060.50
Microbiology of food, animal feed and water — Preparation, production, storage and performance testi...
ISO 11133:2014 defines terms related to quality assurance of culture media and specifies the requirements for the preparation of culture media intended for the microbiological analysis of food, animal feed, and samples from the food or feed production environment as well as all kinds of water intended for consumption or used in food production. These requirements are applicable to all categories…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2014-05-13
Code(s) de l'ICS :
07.100.20; 07.100.30
Safe use of lasers in health care
Scope 1.1 This Standard provides guidance for the safe use of lasers in health care. It applies to all procedures in health care settings where health-related lasers are used, including, but not limited to, the following: a) health care facilities; b) dental clinics, offices, and facilities; c) veterinary facilities; d) laboratories and other research facilities; e) physician offices; f)…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2014-02-28
Code(s) de l'ICS :
91.040.10; 31.260
Medical electrical equipment — Part 2-61: Particular requirements for basic safety and essential per...
This Standard covers ME EQUIPMENT that is intended to be installed or used in accordance with CSA C22.1, Canadian Electrical Code, Part I. Subclause 1.1 of The general standard is replaced by: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of PULSE OXIMETER EQUIPMENT intended for use on humans, hereafter referred to as ME EQUIPMENT. This includes any part…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2014-02-28
Code(s) de l'ICS :
11.040.10

Spacer