Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-0...
This report is a Technical Report and is of a purely informative nature and is therefore by itself not to be regarded as an International Standard. It is to assist users of the standard with determining and recording verification of conformity of the equipment under test with the requirements of: IEC 61010-2-081: 2001The protocol for completion of this report is contained in publication IEC 61010…
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-1...
This report is a Technical Report and is of a purely informative nature and is therefore by itself not to be regarded as an International Standard. It is to assist users of the standard with determining and recording verification of conformity of the equipment under test with the requirements of: IEC 61010-2-101: 2002 The protocol for completion of this report is contained in publication IEC…
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-0...
This report is for use by test houses and other users to assist them with determining and recording verification of conformity of the equipment under test with the requirements of IEC 61010-031:2002.
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3: ...
This part of IEC 61010 is a technical report, which provides a test protocol to assist with determining and recording verification of conformity of the equipment under test with the reference documents identified on the front cover of the appropriate report.
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-1...
This report is a Technical Report and is of a purely informative nature and is therefore by itself not to be regarded as an International Standard. It is to assist users of the standard with determining and recording verification of conformity of the equipment under test with the requirements of: IEC 61010-1: 2001 2nd edition The protocol for completion of this report is contained in publication…
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-0...
This report is a Technical Report and is of a purely informative nature and is therefore by itself not to be regarded as an International Standard. It is for use by users to assist them with determining and recording verification of conformity of the equipment under test with the requirements of: IEC 61010-2-045: 2000 and EC 61010-1: 1990 + amendment 1:1992 + amendment 2:1995
Optics and optical instruments — Lasers and laser-related equipment — Determination of laser resista...
ISO 11990:2003 specifies a method of testing the continuous wave (cw) laser resistance of the shaft of a tracheal tube. Other components of the system, such as the inflation system and cuff, are outside the scope of ISO 11990:2003.
The specified test method shall be used to measure and describe the properties of materials, products or assemblies in response to heat and flame under controlled…
STANDARD TEST METHOD FOR DETERMINATION OF LONG-TERM
THERMAL RESISTANCE OF CLOSED-CELL THERMAL INSUL...
1. SCOPE
1.1 This procedure defines the long-term thermal resistance (LTTR) of a foam product as the value measured after 5-year storage in a laboratory environment and provides means for its prediction based on an accelerated laboratory test.
1.2 This procedure, based on ASTM standard test methods C 1303 and C 518, can be applied to a wide range of preformed as well as field applied…
Soil quality — Pretreatment of samples for determination of organic contaminants
ISO 14507:2003 specifies three methods for the pretreatment of soil samples in the laboratory prior to the determination of organic contaminants:
if volatile organic compounds are to be measured;if moderately volatile to non-volatile organic compounds are to be measured, if the result of the subsequent analysis must be accurate and reproducible, and if the sample contains particles larger than 2…