Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-20...
IEC 61010-2-202:2016 specifies the safety requirements for electric ACTUATORs and SOLENOIDs, as applied to valves, intended to be installed in an industrial process or discrete control environment. This publication is to be read in conjunction with IEC 61010-1:2010.
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
This is the second edition of CAN/CSA-C22.2 No. 61010-2-040, Safety requirements for electrical
equipment for measurement, control, and laboratory use — Part 2-040: Particular requirements for
sterilizers and washer-disinfectors used to treat medical materials, which is an adoption, with Canadian
deviations, of the identically titled IEC (International Electrotechnical Commission) Standard…
Electrostatics - Part 2-3: Methods of test for determining the resistance and resistivity of solid m...
IEC 61340-2-3:2016 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 61340-2-3:2016 describes test methods for the determination of the electrical resistance and resistivity of solid…
Electrostatics - Part 2-3: Methods of test for determining the resistance and resistivity of solid m...
IEC 61340-2-3:2016 describes test methods for the determination of the electrical resistance and resistivity of solid materials used to avoid electrostatic charge accumulation, in which the measured resistance is in the range 10K Ohm to 1T Ohm. It takes account of existing IEC/ISO standards and other published information, and gives recommendations and guidelines on the appropriate method. This…
Guidance on how to conduct round robin tests for household and similar electrical appliances
IEC TR 62970:2016(E) provides guidance for carrying out round robin tests (RRT) and hence for the determination of levels of repeatability (intra-laboratory variability) and reproducibility (inter-laboratory variability) for household and similar electrical appliances. This document can also be used to verify the measurement methods, to improve the measurement method, and to qualify laboratories…
Electroacoustics - Measurement microphones - Part 3: Primary method for free-field calibration of la...
IEC 61094-3:2016 specifies a primary method of determining the complex free-field sensitivity of laboratory standard microphones so as to establish a reproducible and accurate basis for the measurement of sound pressure under free-field conditions. It is applicable to laboratory standard microphones meeting the requirements of IEC 61094-1. It is intended for use by laboratories with highly…
Electroacoustics - Measurement microphones - Part 5: Methods for pressure calibration of working sta...
IEC 61094-5:2016 is applicable to working standard microphones with removable protection grids meeting the requirements of IEC 61094-4 and to laboratory standard microphones meeting the requirements of IEC 61094-1. This part of IEC 61094 describes methods of determining the pressure sensitivity by comparison with either a laboratory standard microphone or another working standard microphone with…
Testing methods for pervious concrete — Part 1: Infiltration rate
ISO 17785-1:2016 specifies the procedure for testing the infiltration rate of hardened pervious concrete pavement specimens in the laboratory. It is not a method for measuring the permeability of pervious concrete. The specimens can either be prepared in the laboratory or cored from field placements, but not representing field conditions. This part of ISO 17785 also specifies procedures to make…
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-0...
IEC 61010-2-020:2016 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 61010-2-020:2016 is applicable to electrically powered LABORATORY CENTRIFUGES. This third edition cancels and…
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-0...
IEC 61010-2-020:2016 is applicable to electrically powered LABORATORY CENTRIFUGES. This third edition cancels and replaces the second edition published in 2006. It constitutes a technical revision and includes the following significant changes from the second edition:
a) This Part 2 is established on the basis of the third edition (2010) of IEC 61010-1. The changes listed in its foreword affect…