End-face image analysis procedure for the calibration of optical fibre geometry test sets
IEC 61745:2017 describes the calibration of test sets that perform end-face image analysis, also known as "near-field" or "grey-scale" analysis. The principles, however, can be applied to test sets of a different type. The procedures outlined are performed by calibration laboratories and by the manufacturers or users of geometry test sets, for the purpose of calibrating…
Soil quality — Laboratory incubation systems for measuring the mineralization of organic chemicals i...
ISO 14239:2017 specifies six suitable incubation systems for measuring the rates and extent of mineralization of organic compounds in soil by measurement of carbon dioxide (CO2) evolution. All incubation systems are applicable to soluble or insoluble compounds but choice of system depends on the overall purposes of the study.
ISO 14239:2017 does not apply to the use of such systems for material…
Protective clothing against heat and flame — Part 1: Test method for complete garments — Measurement...
ISO 13506-1:2017 specifies the overall requirements, equipment and calculation methods to provide results that can be used for evaluating the performance of complete garments or protective clothing ensembles exposed to short duration flame engulfment.
This test method establishes a rating system to characterize the thermal protection provided by single-layer and multi-layer garments made of flame…
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
1 Scope and object
This clause of Part 1 is applicable, except as follows:
1.1.1 Equipment included in the scope
Replacement:
Replace the first paragraph by the following:
This group safety publication is primarily intended to be used as a product safety standard for
the products mentioned in the scope, but shall also be used by technical committees in the
preparation of their publications…
Safety requirements for electrical equipment for measurement, control and laboratory use — Part 2-01...
1 Scope and object
This clause of Part 1 is applicable except as follows:
1.1.1 Equipment included in scope
Replacement:
Replace the first paragraph by the following:
This group safety publication is primarily intended to be used as a product safety standard for
the products mentioned in the scope, but shall also be used by technical committees in the
preparation of their publications for…
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-1: Immu...
IEC 61326-3-1:2017 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 61326-3-1:2017 covers all equipment within the scope of IEC 61326-1, but is limited to systems and equipment…
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immu...
IEC 61326-3-2:2017 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 61326-3-2:2017 covers all equipment within the scope of IEC 61326-1, but is limited to systems and equipment…
Electrical equipment for measurement, control and laboratory use - EMC requirements – Part 3-1: Immu...
IEC 61326-3-1:2017 covers all equipment within the scope of IEC 61326-1, but is limited to systems and equipment for industrial applications intended to perform safety functions as defined in IEC 61508 with SIL 1-3.
This second edition cancels and replaces the first edition published in 2008. This edition constitutes a technical revision. This edition includes the following significant technical…
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immu...
IEC 61326-3-2:2017 covers all equipment within the scope of IEC 61326-1, but is limited to systems and equipment for industrial applications within a specified electromagnetic environment and intended to perform safety functions as defined in IEC 61508 with SIL 1-3.
This second edition cancels and replaces the first edition published in 2008. This edition constitutes a technical revision. This…
Implants for surgery — Orthopaedic joint prosthesis — Part 1: Procedure for producing parametric 3D ...
ISO 19233-1:2017 provides requirements for capturing necessary bone geometries, when using a medical X-ray computed tomography apparatus, to provide the information for applications such as preoperative planning, surgical navigation, robotic surgeries, patient matched instruments and personalized total knee joint prosthesis. The conditions to scan images of bones and the conditions to reconstruct…