Acoustics — Laboratory and field measurement of flanking transmission for airborne, impact and build...
ISO 10848 (all parts) specifies measurement methods to characterize the flanking transmission of one or several building components.
ISO 10848-3:2017 specifies laboratory and field measurements of buildings for Type B elements (defined in ISO 10848‑1) when the junction has a substantial influence.
Laboratory measurements are used to quantify the performance of the junction with suppressed…
Acoustics — Laboratory and field measurement of flanking transmission for airborne, impact and build...
ISO 10848 (all parts) specifies measurement methods to characterize the flanking transmission of one or several building components.
ISO 10848-4:2017 specifies laboratory and field measurements of buildings where at least one of the elements that form the construction under test is a Type A element (defined in ISO 10848‑1).
Laboratory measurements are used to quantify the performance of the…
Determination of RF field strength, power density and SAR in the vicinity of radiocommunication base...
IEC 62232:2017 provides methods for the determination of radio-frequency (RF) field strength and specific absorption rate (SAR) in the vicinity of radiocommunication base stations (RBS) for the purpose of evaluating human exposure. This document:<br />
- considers intentionally radiating RBS which transmit on one or more antennas using one or more frequencies in the range 110 MHz to 100 GHz…
Determination of RF field strength, power density and SAR in the vicinity of radiocommunication base...
IEC 62232:2017 provides methods for the determination of radio-frequency (RF) field strength and specific absorption rate (SAR) in the vicinity of radiocommunication base stations (RBS) for the purpose of evaluating human exposure. This document:
- considers intentionally radiating RBS which transmit on one or more antennas using one or more frequencies in the range 110 MHz to 100 GHz;
-…
Ships and marine technology — Test method of flow induced in-pipe noise source characteristics for a...
ISO 20155:2017 specifies a test method for determining flow induced in-pipe noise source characteristics of a ship-used pump as a two-port sound source in laboratory conditions by measuring acoustic pressures in the pipe reaches of inlet and outlet.
The test method is applicable to all types of centrifugal pumps with a diameter over 50 mm operating under steady conditions.
The suitable frequency…
Method for measuring photovoltaic (PV) glass - Part 2: Measurement of transmittance and reflectance
IEC 62805-2:2017 specifies methods for measuring the transmittance and reflectance of glass used in photovoltaic (PV) modules and provides instructions on how to calculate the effective hemispherical transmittance and reflectance of this glass. This document is applicable to PV glasses used in PV modules, including ultra-clear patterned glass, anti-reflective coated (AR) glass, transparent…
Paints and varnishes — Determination of pH value — Part 1: pH electrodes with glass membrane
ISO 19396-1:2017 specifies a method for laboratory measurement of the pH value of polymer dispersions and coating materials using pH electrodes with a glass membrane. ISO 19396‑2 specifies a method for measuring the pH value using pH electrodes with ion-sensitive field-effect transistor (ISFET) technology.
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity ...
IEC 61000-4-5:2014+A1:2017 relates to the immunity requirements, test methods, and range of recommended test levels for equipment with regard to unidirectional surges caused by over-voltages from switching and lightning transients. Several test levels are defined which relate to different environment and installation conditions. These requirements are developed for and are applicable to…
Rubber, vulcanized — Determination of adhesion to wire cord
ISO 5603:2017 specifies two methods for determining the adhesion strength of vulcanized rubber to wire cord which is embedded in the rubber.
The two methods do not necessarily give the same results.
They are applicable primarily to test pieces prepared in the laboratory under standard conditions and used for the development and control of materials and processes utilized in the manufacture of…
End-face image analysis procedure for the calibration of optical fibre geometry test sets
IEC 61745:2017 describes the calibration of test sets that perform end-face image analysis, also known as "near-field" or "grey-scale" analysis. The principles, however, can be applied to test sets of a different type. The procedures outlined are performed by calibration laboratories and by the manufacturers or users of geometry test sets, for the purpose of calibrating…