Sodium perborates for industrial use — Determination of rate of solution — Conductivity method
Gives a conductive method for determining the rate of solution. Describes the principles of the procedure by dissolution of an agreed test portion in water at an agreed temperature, with controlled agitation. Measurement of the conductivity of the solution, at certain intervals, of the final conductivity (when the sample is completely dissolved) and calculation of the ratio of conductivities to…
Potassium chloride for industrial use — Determination of potassium content — Flame emission spectrop...
Is applicable to products having a minimum KCl content of about 95 % (m/m). The principle consists in dissolution of a test portion taken from the laboratory sample, previously ground and sifted. Acidification to pH 1 after suitable dilution, and atomization of the resultant solution in the burner of a flame spectrophotometer. Measurement of the intensity of the 766 nm ray, compared with the…
Statistical interpretation of data — Comparison of two means in the case of paired observations
A method is specified for comparing the mean of a population of differences with zero or any other preassigned value. It may be applied to establish a difference between two treatments, where "treatment" should be understood in a wide sense, e.g. as a test method, measuring instrument or laboratory involved, and is applicable under the conditions that the series of differences can be…
Solid dielectric tubular-style rotary variable pre-set capacitors: Grade 2. Part 1: General requirem...
Establishes under laboratory conditions: their suitability for use
over stated ranges of temperature, air pressure and humidity, their
ability to withstand specified conditions of mechanical shock,
their ability to withstand the rigours of normal assembly
processes.
Ceramic dielectric disk-style rotary variable pre-set capacitors: Grade 2. Part 1: General requireme...
Describes the tests on capacitors to establish as far as possible under laboratory conditions: their suitability for use over stated ranges of temperature, air pressure and humidity; their ability to withstand specified conditions of mechanical shock such as are to be expected under transit or operational conditions: their
ability to withstand the rigours of normal assembly processes attendant on…
Air dielectric rotary variable capacitors. Part 1: General requirements for tests and measuring meth...
Describes tests that establish, as far as possible under laboratory conditions, their suitability for use and their ability to withstand specified conditions of mechanical shock and rigours of normal assembly processes. A guide to the use and testing of air dielectric rotary variable capacitors is given in an appendix.
Applies to new voltage transformers for use with electrical measuring instruments and electrical protective devices at frequencies from 15 Hz to 100 Hz.
The general requirements apply to all voltage transformers, but, for certain types, e.g. capacitor voltage transformers, the requirements are subject to the modifications stated in the appropriate chapter. Although the requirements relate…
Lays down the conditions and procedure for carrying out impulse tests on cables and their accessories, with a view to rationalizing the practice in different laboratories, and thus to facilitate valid comparisons between the results obtained on cables made to different specifications.
Notes:
1.This publication should be read in conjunction with IEC 60060 and 60141.
2.For voltage measurements…