Safety requirements for electrical equipment for measurement, control and laboratory use — Part 2-10...
The following deviations are intended to meet Canadian product requirements and to align with the
Canadian Electrical Code, Part I.
International Standard IEC 61010-2-101:2015 (second edition) forms the basis for
CAN/CSA-C22.2 No. 61010-2-101, which contains the following deviations in addition to those shown in
CAN/CSA-C22.2 No. 61010-1:12.
Les exigences propres au Canada qui suivent…
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
Replace the text in 1,1 by the following paragraph:
This part of IEC 61010 is applicable to electrically operated laboratory equipment and its
accessories for mechanical mixing and stirring, where mechanical energy influences the
shape or size or homogeneity of materials and their accessories. Such devices may contain
heating elements.
NOTE If all or part of the equipment falls within the…
ISO 13350:2015 deals with the determination of those technical characteristics needed to describe all aspects of the performance of jet fans as defined in ISO 13349. It does not cover those fans designed for ducted applications, nor those designed solely for air circulation, e.g. ceiling fans and table fans.
The test procedures described in this International Standard relate to laboratory…
ISO 10650:2015 specifies requirements and test methods for powered polymerization activators in the 385 nm ? 515 nm wavelength region intended for chairside use in polymerization of dental polymer-based materials. This International Standard applies to quartz-tungsten-halogen lamps and light-emitting diode (LED) lamps. Powered polymerization activators could have internal power supply (…
Workplace atmospheres — Short term detector tube measurement systems — Requirements and test methods
ISO 17621:2015 specifies requirements and test methods under prescribed laboratory conditions for length-of-stain detector tubes and their associated pump (detector tube measurement system) used for short-term measurements of the concentration of specified chemical agents in workplace air.
ISO 17621:2015 is not applicable to measurements made to demonstrate compliance with long-term limit values…
Alpine and touring ski-bindings — Test soles for ski-binding tests
ISO 9838:2015 defines test soles representing
- an alpine ski-boot (form A) or at least the bottom part of it to be used for testing alpine ski-bindings for alpine skiing in accordance with ISO 9462 and ISO 9465, and
- a touring ski-boot (form T) or at least the bottom part of it to be used for testing touring ski-bindings for touring skiing in accordance with ISO 13992 and ISO 9465.…
1.1
This Standard applies to all types of laboratory fume hoods, except for ductless fume hoods.
Note: Ductless fume hoods should not be considered acceptable substitutes for ducted fume hoods. Some
jurisdictions prohibit use of ductless fume hoods with certain chemicals. For these reasons, ductless fume hoods
have not been included in this Standard.
1.2
This Standard specifies
a) safety…
1.1
This Standard specifies requirements for the packaging, collection, handling, storage, and on-site treatment and disposal of health care waste materials.
1.2
1.2.1
This Standard applies to health care and veterinary–related waste, and health care–related waste generated in non-traditional health care settings.
1.2.2
“Health care and veterinary” refers to
a)
health care facilities and…
Petroleum and natural gas industries — Specific requirements for offshore structures — Part 8: Marin...
ISO 19901-8:2014 specifies requirements, and provides recommendations and guidelines for marine soil investigations regarding:
a) objectives, planning and execution of marine soil investigations;
b) deployment of investigation equipment;
c) drilling and logging;
d) in situ testing;
e) sampling;
f) laboratory testing; and
g) reporting.
Rock materials are only covered by ISO 19901-8:2014 to…
Electromagnetic compatibility (EMC) - Part 4-38: Testing and measurement techniques - Test, verifica...
IEC TR 61000-4-38:2015(E) defines a test protocol for flicker test systems designed to perform compliance tests in accordance with IEC 61000-3-3 and IEC 61000-3-11. It is intended to provide test system manufacturers and testing laboratories with systematic methods to determine if the flicker test system meets the IEC design specifications for a wide range of voltage fluctuations and fluctuation…