Testing of concrete — Part 14: Setting time of concrete mixtures by resistance to penetration
This document covers the method for determining the setting time of concrete with slump greater than zero, by testing mortar sieved from the concrete mixture. The initial setting time and the final setting time are the time intervals required for the mortar sieved from the concrete mixture to reach the specified values of penetration resistance after the initial contact of cement and water.
The…
Microbiology of the food chain — Method validation — Part 6: Protocol for the validation of alternat...
This document specifies the general principle and the technical protocol for the validation of alternative confirmation methods for microbiology in the food chain. This document compares the result of the alternative confirmation method against the confirmation procedure of a reference method or, if needed, a reference confirmation method (e.g. whole genome sequencing).
This document is…
Biorisk management for laboratories and other related organisations
This document defines a process to identify, assess, control, and monitor the risks associated with hazardous biological materials. This document is applicable to any laboratory or other organization that works with, stores, transports, and/or disposes of hazardous biological materials. This document is intended to complement existing International Standards for laboratories.
This document is not…
Personal identification - ISO-compliant driving licence - Part 4: Test methods
This document describes the test methods used for conformity testing, that is methods for determining whether a driving licence can be considered to comply with the requirements of the ISO/IEC 18013 series for:
— machine readable technologies (ISO/IEC 18013-2), and
— access control, authentication and integrity validation (ISO/IEC 18013-3).
The test methods described in this document are…
Personal identification — ISO-compliant driving licence — Part 4: Test methods
This document describes the test methods used for conformity testing, that is methods for determining whether a driving licence can be considered to comply with the requirements of the ISO/IEC 18013 series for:
— machine readable technologies (ISO/IEC 18013-2), and
— access control, authentication and integrity validation (ISO/IEC 18013-3).
The test methods described in this document are…
Flexible and rigid cellular polymeric materials — Accelerated ageing tests
This document specifies, for flexible and rigid cellular polymeric materials, laboratory procedures which are intended to imitate the effects of naturally occurring reactions such as oxidation or hydrolysis by humidity. The physical properties of interest are measured before and after the application of the specified treatments.
Test conditions are only given for open cellular latex, both open-…
Safety requirements for electrical equipment for measurement, control and laboratory use — Part 2-01...
1 Scope and object
This clause of Part 1 is applicable except as follows:
1.1.1 Equipment included in scope
Replacement:
This part of IEC 61010 specifies safety requirements for electrically powered laboratory
equipment for the heating of materials, where the heating of materials is one of the functions
of the equipment.
NOTE If all or part of the equipment falls within the scope of one or…
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
1.1 Scope
[Add the following]
This Standard applies to the above-noted equipment that is intended to be installed or used in
accordance with CSA C22.1, Canadian Electrical Code, Part I.
General requirements applicable to this Standard are provided in CAN/CSA-C22.2 No. 0.
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
1.1 Scope
1.1.1 Equipment included in Scope
[Add the following]
This Standard applies to the above-noted equipment that is intended to be installed or used in
accordance with CSA C22.1, Canadian Electrical Code, Part I.
General requirements applicable to this Standard are provided in CAN/CSA-C22.2 No. 0.
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
1 Scope and object
This clause of part 1 is applicable except as follows:
1.1.1 Equipment included in scope
Replacement:
Replace the text by the following:
This part of IEC 61010 applies to automatic and semi-automatic laboratory equipment for
analysis and other purposes.
Automatic and semi-automatic laboratory equipment consists of instruments or systems for
measuring or modifying one or…