Standard Method of Fire Test of Exterior Wall Assemblies
1.1 This test method enables an assessment of the fire spread characteristics
of non-loadbearing exterior wall assemblies.
1.2 The test determines the comparative burning characteristics of exterior
wall assemblies by evaluating the following:
A Fire spread over the exterior surface;
B Heat flow from the fire plume to the exterior surface; and
C Fire spread within the test specimen.
1.3…
1.1
This Standard provides procedures for evaluating polymeric materials intended
for application in electrical equipment covered by the Canadian Electrical
Code, Part I, with respect to the following properties:
(a) flammability;
(b) mechanical;
(c) thermal;
(d) resistance to weathering; and
(e) electrical.
1.2
The test procedures listed in this Standard are provided for…
1.1
This Standard applies to medical gas piping systems for conducting nonflammable
medical gases used for patient care in health care facilities. Included in
this Standard are requirements pertaining to small systems such as those
serving dental suites, as well as systems providing nonflammable medical gases
to laboratories.
Notes:
(1) The manufacture, control, and distribution of…
Earth-moving machinery — Determination of slope limits for machine fluid systems operation — Static ...
Applies to earth-moving machines as given in ISO 6165. Specifies laboratory test procedures evaluating the limiting performance parameters. Fluid systems include engine, power train, fuel system, oil system, etc. The preferred test method is with the machine on a tilt platform or on a prepared slope. An alternative method is testing on a test bench. Annex A shows a model test report.
Measurement of liquid flow in open channels — Tracer dilution methods for the measurement of steady ...
Describes the tracers used (bromine 82, tritium, iodine 131, indium 113 m, cesium 131, ytterbium 168), the tracer measurement (principle, field measurement and laboratory measurements), environmental factors affecting tracers, techniques for tracer injection, sampling techniques, estimation of uncertainties.
Measurement of liquid flow in open channels — Tracer dilution methods for the measurement of steady ...
Describes the tracers used (iodide, lithium, chloride, chromium), the tracer measurement (principle, field measurement and laboratory measurements), environmental factors affecting tracers, techniques for tracer injection, sampling techniques, analysis and sources of error.
Measurement of liquid flow in open channels — Tracer dilution methods for the measurement of steady ...
Describes the tracers used (fluorescein, rhodamine B, acid yellow 7, sulfo rhodamine B, pyranine, and rhodamine WT), the tracer measurement (principle, field measurement and laboratory measurements), environmental factors affecting tracers, techniques for tracer injection, sampling techniques, analysis and computation.
Manganese ores and concentrates — Determination of hygroscopic moisture content in analytical sample...
The method is based on drying of an air-dried test portion to constant mass in a laboratory oven at 105 °C to 110 °C, and measurement of the loss in mass. The determination is intended to be carried out simultaneously with that of other constituents of the same analytical sample, so that the contents of the other constituents can be calculated on the basis of the absolutely dry ore. Should be…