Paints and varnishes — Determination of release rate of biocides from antifouling paints — Part 5: C...
ISO 15181-5:2008 specifies the apparatus and analytical method for determining the amount of tolylfluanid and dichlofluanid that has been released from an antifouling paint into artificial seawater in accordance with the procedure given in ISO 15181-1.
Tolylfluanid and dichlofluanid are unstable in the marine environment and degrade to form dimethyltolylsulfamide (DMST) and…
Medical laboratories — Reduction of error through risk management and continual improvement
ISO/TS 22367:2008 characterizes the application of ISO 15189 as a system for reducing laboratory error and improving patient safety by applying the principles of risk management, with reference to examination aspects, especially to pre- and post-examination aspects, of the cycle of laboratory medical care. ISO/TS 22367:2008 proposes a methodology for finding and characterizing medical laboratory…
Hydraulic fluid power — Monitoring the level of particulate contamination of the fluid — Part 3: Use...
ISO 21018-3:2008 specifies a method for the semi-quantitative determination of the particulate contamination level using the filter blockage technique (also known as the mesh-obscuration method or the pore-blockage technique) either on-line or off-line in containers. ISO 21018-3:2008 also defines procedures for calibrating the instruments and verifying their correct operation both in the…
Protective clothing against heat and flame — Test method for complete garments — Prediction of burn ...
ISO 13506:2008 provides the general principles of a test method for evaluating the performance of complete garments or protective clothing ensembles in a flash fire or other short duration exposures. This test method characterizes the thermal protection provided by garments, based on the measurement of heat transfer to a full-size manikin exposed to a laboratory simulation of a fire with…
Soil quality — Preparation of laboratory samples from large samples
ISO 23909:2008 specifies a method for the preparation of laboratory samples from large samples. In accordance with ISO 11464 and ISO 14507, the following analyses are considered: determination of physico-chemical parameters, determination of moderate volatile organic contaminants, and determination of non-volatile contaminants.
ISO 23909:2008 is not applicable when volatile organic compounds have…
ISO 12789-2:2008 describes the characterization of simulated workplace neutron fields produced by methods described in ISO 12789-1. It specifies the procedures used for establishing the calibration conditions of radiation protection devices in neutron fields produced by these facilities, with particular emphasis on the scattered neutrons. The diversity of workplace neutron fields is such that…
Reference radiation fields — Simulated workplace neutron fields — Part 1: Characteristics and method...
ISO 12789-2:2008 describes the characterization of simulated workplace
neutron fields produced by methods described in ISO 12789-1. It specifies the
procedures used for establishing the calibration conditions of radiation
protection devices in neutron fields produced by these facilities, with
particular emphasis on the scattered neutrons. The diversity of workplace
neutron fields is such…
Management of Low- and Intermediate-Level Radioactive Waste
1 Scope
1.1
This Standard specifies requirements for the management of low- and intermediate-level radioactive waste in solid, liquid, or gaseous states.
1.2
This Standard applies to organizations and facilities that generate, possess, manage, and transport lowand intermediate-level radioactive waste, including power reactors, research institutes, laboratories, and industrial facilities…