Méthode d'essai normalisée pour évaluer le potentiel incendiaire des cigarettes
Le présent document spécifie une méthode d’essai pour évaluer la capacité d’une cigarette, positionnée sur un des trois substrats normalisés, à s’éteindre ou à générer suffisamment de chaleur pour continuer à se consumer et, par conséquent, à potentiellement mettre le feu à la literie ou aux meubles rembourrés. Le présent document s’applique aux cigarettes manufacturées se consumant sur la…
Consumer vulnerability — Requirements and guidelines for the design and delivery of inclusive servic...
This document specifies requirements and guidelines for organizations on how to design and deliver fair, flexible and inclusive services that will increase positive outcomes for consumers in vulnerable situations and minimize the risk of consumer harm. It covers organizational culture and strategy, inclusive design and how to identify and respond to consumer vulnerability.
It is applicable to any…
Information technology — Data centres key performance indicators — Part 6: Energy Reuse Factor (ERF)
1 Scope
This document specifies the energy reuse factor (ERF) as a KPI to quantify the reuse of the energy consumed in a data centre. ERF is defined as the ratio of energy being reused divided by the sum of all energy consumed in a data centre. The ERF does reflect the efficiency of the reuse process; the reuse process is not part of a data centre.
Paints and varnishes — Electro-deposition coatings — Part 10: Edge protection
This document specifies a test method for the evaluation of protection against corrosion of edges and stamping burrs by electro-deposition coatings.
It applies to electro-deposition coatings for automotive industries and other general industrial applications, e.g. chiller units, consumer products, radiators, aerospace, agriculture.
Photovoltaic direct-driven appliance controllers - Part 2: Operation modes and graphic display
IEC TS 63349-2:2022 defines operation modes of photovoltaic direct-driven appliance (PVDDA) controllers and describes one example of a graphic display. The graphic display is an interface to PVDDA users, which uses easily understood graphics to show a real-time operation mode, such as what equipment is installed, controlled and monitored in the system, which equipment is generating power and how…
Portable containers for gasoline and other petroleum fuels
1 Scope
1.1 Inclusions
This Standard sets forth a set of minimum performance requirements for PFCs up to and including 32 L (8.45 US gallons) rated capacity, made from steel or plastic, and intended for re-use by consumers for the transportation and temporary outdoor storage of petroleum-based flammable and combustible liquids. It includes dual compartment PFCs for separate gas and oil storage…
Gas pressure safety and control devices for use in gas transmission, distribution and installations ...
This document specifies generic safety, constructional, performance, testing and documentation requirements for high pressure controls for use in gas transmission, distribution and installations (hereafter referred to as controls).
This document is applicable to controls with operating pressures greater than 500 kPa (5 bar) and up to and including 10 MPa (100 bar) and nominal size up to DN 400…
Gas pressure safety and control devices for use in gas transmission, distribution and installations ...
This document specifies safety, constructional, performance, testing and documentation requirements for gas pressure regulators for use in gas transmission and distribution installations (hereafter referred to as regulators).
This document is applicable to regulators with operating pressures greater than 500 kPa and up to and including 10 MPa (100 bar) and nominal diameters up to DN 400 for use…
Energy management system application program interface (EMS-API) - Part 456: Solved power system sta...
IEC 61970-456:2021 belongs to the IEC 61970-450 to IEC 61970-499 series that, taken as a whole, defines at an abstract level the content and exchange mechanisms used for data transmitted between power system analyses applications, control centres and/or control centre components.
The purpose of this document is to rigorously define the subset of classes, class attributes, and roles from the CIM…
Protective gloves against thermal risks (heat and/or fire)
This document specifies requirements, test methods, marking and information for protective gloves and other hand protective equipment against thermal risks for professional use, consumer, domestic use.
This document is also applicable to arm protective equipment.
It is used for all gloves and other hand protective equipment which protect the hands or part of the hand against heat and/or fire in…