1. Scope
1.1 This Standard applies to cord-connected household and commercial irons of the steam or dry type, with or without automatic temperature control, for voltages of 250 V and less, designed to be used in accordance with the Rules of the Canadian Electrical Code, Part I.
1.2 This Standard applies to irons intended for general household and commercial clothes ironing use in nonhazardous…
Electric fence energizers - Safety requirements for battery-operated electric fence energizers not f...
Applies to battery-operated electric fence energizers not for connection to the supply mains.
Examples of such appliances are electric fence energizers
-operated by non-rechargeable batteries either incorporated or separate;
-operated by separate accumulators only;
-intended to be connected to a battery charger not designed for connection to the supply mains;
-incorporating a dry battery or an…
Connecting devices for low voltage circuits for household and similar purposes. Part 1: General requ...
Applies to connecting devices as separate entities for the connection of two or more electrical copper conductors, rigid or flexible, having a cross-sectional area of 0.5 mm2 up to and including 35 mm2 with a rated voltage not exceeding 1 000 V a.c. up to and including 1 000 Hz and 1 500 V d.c. where electrical energy is used for household and similar purposes. This publication supersedes IEC…
1. Scope
1.1
This standard applies to motor-operated gardening appliances* intended for use
on nominal system voltages of 250 V and less and in nonhazardous locations, and
designed to be used in accordance with the Rules of the Canadian Electrical
Code, Part I.
*For convenience, the short terms "appliance", "equipment", and "machine" are
used herein.
1.2
This…
1.1
Applies to equipment intended to be electrically connected to a
telecommunication network and receives its power from the telecommunication
network alone, or from an ac or dc source, or from any combination thereof.
The network has a normal operating voltage to ground of less than 150 V rms and
the equipment is designed to be operated in nonhazardous locations in
accordance with the…
Construction and Test of Electric Storage-Tank Water Heaters
Applies to both cord-connected and permanently connected
storage-tank water heaters, having tanks less than 610 mm inside
diameter, for use on nominal system voltages of 600 V and less,
and designed to be used in nonhazardous household and commercial
locations in accordance with the Rules of the Canadian Electrical
Code, Part I.
1.1
Applies to apparatus whose purpose is to transmit and receive and process radio
signals and signals of voice, musical or visual origin and that operates from a
supply circuit not exceeding 120 V in accordance with the Rules of the Canadian
Electrical Code, Part I and which is not necessarily under the jurisdiction of
a skilled person. Processing of electronic signals includes…
Cylinder valve outlets for gases and gas mixtures — Selection and dimensioning
Establishes practical criteria for determining valve outlet connections for gas cylinders of a capacity not greater than 150 l. Applies particullary to countries having neither standards nor regulations and to new gases developed for industrial use. I does not apply to connections used for cryogenic gas groups; annex B deals with connections; double-faucet non-interchangeable connections are…