Safety of household and similar electrical appliances - Part 2: Guide for
preparing safety requirem...
This National Standard of Canada is based on International Standard CEI/IEC 335-2-18:1984.
1. Scope
This clause of Part | is applicable except as follows:
1.1 Replacement:
This guide applies to rechargeable battery-powered motor-operated appliances
for household and similar purposes having a rated input not exceeding 20 VA,
and to their charging and battery assemblies where…
Safety of household and similar electrical appliances - Part 2: Particular requirements for battery-...
This National Standard of Canada is based on International Standard CEI/IEC 335-2-19:1984.
1. Scope
This clause of Part 1 is applicable except as follows:
1.1 Replacement:
This standard applies to rechargeable battery-powered motor-operated shavers,
hair clippers and appliances for massage, manicure, pedicure and similar
purposes, and to their charging and battery assemblies where…
Safety of household and similar electrical appliances - Part 2: Particular requirements for oral hyg...
1. Scope
This clause of Part 1 is applicable, except as follows:
1.1 Replacement:
This standard applies to oral hygiene appliances, such as tooth-brushes and oral irrigator devices (sprays) which are connected to the mains supply through a safety isolating transformer.
The transformer is mechanically separated from the part held in the hand.…
Electromagnetic compatibility (EMC) - Part 4: Testing and measuring techniques - Section 11: Voltage...
This standard defines the immunity test methods and range of preferred test levels for electrical and electronic equipment connected to low voltage power supply networks for voltages dips, short interruptions, and voltage variations. It applies to electrical and electronic equipment having a rated input current not exceeding 16 A per phase. It does not apply to electrical and electronic equipment…
Metallic tube connections for fluid power and general use — Part 1: 24 degree compression fittings
Specifies general (pressure, temperature, designation, assembly, marking) and dimensional requirements for the design and performance of 24° compression fittings which are suitable for use with ferrous and non-ferrous tubes with outside diameters from 4 mm to 42 mm, inclusive. These fittings are for use in fluid power and general applications within the limits of pressure and temperature…
Information technology — International Standardized Profile TAnnnn — Connection-mode Transport Servi...
ISO/IEC ISP 10608 is applicable to end systems concerned with operating in the open systems interconnection (OSI) environment. It specifies a combination of OSI standards which collectively provide the connection-mode transport service using the connectionless network service. This part is applicable to the provision of the connection-mode transport service in end systems attached to a token ring…
Information technology — International Standardized Profile TAnnnn — Connection-mode Transport Servi...
Is applicable to end systems or relay systems operating over token ring LAN subnetworks in the open systems interconnection (OSI) environment. Relates to any of the transport (Tx, Ux) or relay (Rx) profiles defined in ISO/IEC TR 10000-2, where such profile uses subnetwork type 53. Specifically, provides a common set of requirements that are applicable to transport groups TA, TB, TC, TD, TE, UA,…
1.1
This standard applies to asbestos-cement, nonpressure, small-diameter pipe,
suitable for use as building sewer pipe and as building drain pipe buried under
the floor.
1.2
For cautionary notes on cutting, sanding, grinding or drilling of this product,