Specifies requirements for the design and performance of the fittings, being for general purposes for the transmission of fluids and gases up to the limits of pressure and temperature specified. They are intended for the connection of elements threaded in accordance with ISO 7/1, sizes 1/8 to 6. For use in conditions outside the pressure and temperature limits specified, consult the fitting…
Information technology - Open Systems Interconnection - Presentation service definition
Defines in an abstract way the externally visible service provided by the OSI presentation layer in terms of the primitive actions and events at the user/service boundary, the parameter data associated with each primitive action and event, the relationship between, and the valid sequences of, those actions and events. The service defined is the connection-oriented service which is provided by the…
Telecontrol equipment and systems - Part 6: Telecontrol protocol s compatible with ISO standards and...
Defines the functional profile which provides the connection-oriented transport service in an end system connected via permanent access to a packet switched data network.
This publication is of high relevance for Smart Grid.
Matériels et systèmes de téléconduite - Partie 6: Protocoles de
téléconduite compatibles avec les n...
Définit le profil fonctionnel qui fournit le service de transport en mode connexion dans un système d'extrémité connecté par un accès permanent à un réseau de commutation de paquets.
Electromagnetic compatibility (EMC) - Part 3: Limits - Section 5: Limitation of voltage fluctuations...
The recommendations in this Technical Report are applicable to electrical and electronic equipment intended to be connected to a public low-voltage a.c. distribution system, where the equipment has a rated input current exceeding 16 A per phase, or has a lower rated current, but requires the special consent of the supply authority.
This publication has the status of a technical report - type 2
Information technology — Open Systems Interconnection — Connection-oriented presentation protocol: P...
Cancels and replaces the first edition (1988). Specifies procedures for the transfer of data and control information from one presentation-entity to a peer presentation-entity; the means of selecting, by means of functional units, the procedures to be used by the presentation-entities; the structure and encoding of the presentation-protocol-data-units used for the transfer of data and control…
Information technology — Microprocessor systems — Futurebus+ — Logical protocol specification
Specifies the logical layer for a set of signal lines that constitute a multiple segment bus architecture, and for the interfacing of modules connected to a bus segment. Intended to be used as a component within a profile to build systems with higher levels of compatibility.
Information technology - Open Systems Interconnection - Connection-oriented presentation protocol: P...
Cancels and replaces the first edition (1988). Specifies procedures for the transfer of data and control information from one presentation-entity to a peer presentation-entity; the means of selecting, by means of functional units, the procedures to be used by the presentation-entities; the structure and encoding of the presentation-protocol-data-units used for the transfer of data and control…
Information technology - Microprocessor systems - Futurebus+ - Logical protocol specification
Specifies the logical layer for a set of signal lines that constitute a multiple segment bus architecture, and for the interfacing of modules connected to a bus segment. Intended to be used as a component within a profile to build systems with higher levels of compatibility.
Commercial vehicles with 24 V systems — 15-pole connectors between towing vehicles and trailers — Di...
Specifies dimensions and specific requirements for the 15-pole connector and its contact allocation to enable electrical connection between commercial towing vehicles and their trailers equipped with 24 V systems to be made and to ensure interchangeability. Further specifies a park socket used to receive and store the plug when it is disconnected. Annex A specifies characteristics of two adaptors…