Rechercher

Affiner les résultats
Code de la Classification internationale pour les normes (ICS)
Source
Code de l’organisme d’élaboration de normes (OEN)
Langue
Statut
Code de la Norme nationale du Canada (NNC)
Date de publication

De

à

Affichage 4311 - 4320 de 5905
SBus - Chip and module interconnect bus
An input/output expansion bus with a 32- or 64-bit width is described in this standard. The SBus is designed for systems requiring a small number expansion ports. SBus Cards may be connected to a standard Sbus Connector mounted on the motherboard. SBus Devices may also be attached to the SBus directly on the system's motherboard. The dimensions of the SBus Card are 83,8 mm by 146,7 mm,…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2000-06-27
Code(s) de l'ICS :
35.160
Information technology — Fibre Channel — Part 131: Switch Fabric Requirements (FC-SW)
This ISO/IEC standard for FC-SW specifies tools and algorithms for interconnection and initialization of Fibre Channel switches to create a multi-switch Fibre Channel Fabric. This Standard defines an E_Port (ìExpansion Portî) that operates in a manner similar to an N_Port and F_Port, as defined in ISO/IEC 14165- 111, with additional functionality provided for interconnecting switches. This…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2000-06-14
Code(s) de l'ICS :
35.200
Mechanical vibration and shock — Vibration and shock in buildings with sensitive equipment — Part 1:...
This part of ISO/TS 10811 defines methods of measurement, algorithms for analysis and the report of shock and vibration data for equipment in buildings which is sensitive to shock and vibration. The methods are applicable to the quantification of a future installation or the verification of an existing one. Accurate vibration data acquisition, analysis and uniform reporting methods are needed to…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2000-06-07
Code(s) de l'ICS :
17.160; 91.120.25
Mechanical vibration and shock — Vibration and shock in buildings with sensitive equipment — Part 2:...
This part of ISO/TS 10811 defines a method for the classification of shock and vibration in buildings from measurements in accordance with ISO/TS 10811-1. A classification system of environmental vibration conditions should serve as guidelines for designers, manufacturers and users of equipment sensitive to shock and vibration, and for building constructors. The types of shock and vibration…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2000-06-07
Code(s) de l'ICS :
17.160; 91.120.25
Road vehicles — Diagnostic systems — Keyword Protocol 2000 — Part 4: Requirements for emission-relat...
This part of ISO 14230 specifies the requirements for the Keyword Protocol 2000 (KWP 2000) data link and connected vehicle and scan tool when used to comply with on-board diagnostic (OBD) requirements for emission-related test data. This part of ISO 14230 only specifies requirements relative to the Keyword Protocol 2000 for OBD purposes. Complete specification can be found in ISO 14230 parts 1 to…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2000-06-07
Code(s) de l'ICS :
43.180
Inhalational Anaesthesia Systems - Part 3: Anaesthetic gas scavenging systems - Transfer and receiv...
International Standard ISO 8835-3:1997 has been adopted with Canadian deviations as CSA Standard CAN/CSA-Z8835-3-00. 1 Scope This part of ISO 8835 specifies requirements for transfer and receiving systems of active anaesthetic gas scavenging systems (AGSS) intended to reduce the exposure of hospital personnel to anaesthetic gases and vapours. It does not apply to nonactive AGSS (…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2000-05-31
Code(s) de l'ICS :
11.040.10
Terminal Units for Medical Gas Pipeline Systems - Part 1: Terminal Units for Use with Compressed Med...
International Standard ISO 9170-1:1999 has been adopted with Canadian deviations as CSA Standard CAN/CSA-Z9170-1-00. 1 Scope This part of ISO 9170 specifies requirements for terminal units intended for use in medical gas pipeline systems in accordance with ISO 7396-1, for use with the following services: - oxygen; - nitrous oxide; - air for breathing; - carbon dioxide; - oxygen/nitrous…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2000-05-31
Code(s) de l'ICS :
11.040.10
Terminal Units for Medical Gas Pipeline Systems - Part 2: Terminal Units for Anaesthesia Gas Scaven...
International Standard ISO 9170-2:1999 has been adopted with Canadian deviations as CSA Standard CAN/CSA-Z9170-2-00. 1 Scope This part of ISO 9170 specifies the requirements and dimensions for terminal units intended for use in anaesthetic gas scavenging disposal systems in accordance with ISO 7396-2. It is intended especially to ensure the type specificity of terminal units and…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2000-05-31
Code(s) de l'ICS :
11.040.10
Connectors for frequencies below 3 MHz - Part 9: Circular connectors for radio and associated sound ...
Relates to circular connectors for radio and associated sound equipment. Specifies IEC type designations, contact arrangements and connections, dimensions, gauges, rated values, and schedules for type tests.
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2000-05-17
Code(s) de l'ICS :
31.220.10
Safety of equipment electrically connected to a telecommunication network
IEC 62151:2000 Applicable to equipment designed and intended to be connected directly to a Telecommunication Network, regardless of the source of power. This basic safety publication is primarily intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 104 and ISO/IEC Guide 51. It is not intended for use by manufacturers or…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2000-05-04
Code(s) de l'ICS :
33.020; 35.020