Sleep apnoea breathing therapy — Part 2: Masks and application accessories
ISO 17510-2:2002 specifies requirements for masks and accessories which are required to connect the patient connection port to a sleep apnoea breathing therapy device and the mask to a patient, and are used for the application of sleep apnoea breathing therapy, e.g. nasal masks, gas exhaust ports, connecting elements and headgear.
ISO 17510-2:2002 does not cover oral appliances.
NOTE 1 Sleep…
1 Scope
1.1
This Standard specifies the safety requirements for medical supply units for application in medical areas, such as general wards, as well as in special purpose areas, such as operating theatres, induction rooms, recovery wards, dialysis units, intensive care or therapy units, and other intermediate care areas. Medical supply units are intended to supply medical gases, either singly…
Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particula...
This standard applies to connecting devices with screwless-type clamping units primarily suitable for connecting unprepared conductors. This Part 2-1 is intended to be used in conjunction with IEC 60998-1. It was established on the basis of the second edition (2002) of that standard. This second edition cancels and replaces the first edition published in 1991 and constitutes a technical revision.
Connecting devices for low-voltage circuits for household and similar purposes - Part 2-3: Particula...
This standard applies to connecting devices with insulation piercing clamping units primarily suitable for connecting insulated unprepared conductors. In the connecting operation the insulation of the conductor is pierced, bored through, cut through, removed, displaced or made ineffective in some other manner at the point or points of contact. This Part 2-1 is intended to be used in conjunction…
Connecting devices for low-voltage circuits for household and similar purposes - Part 2-1: Particula...
This standard applies to connecting devices with screw-type clamping units primarily suitable for connecting unprepared conductors. This Part 2-1 is intended to be used in conjunction with IEC 60998-1. It was established on the basis of the second edition (2002) of that standard. This second edition cancels and replaces the first edition published in 1990 and constitutes a technical revision.
Electrical installations for lighting and beaconing of aerodromes - AGL series transformers
IEC 61823:2002 specifies the characteristics of aeronautical ground lighting series trans-formers (AGLST) used in aeronautical ground lighting for 6,6 A series circuits, at a service voltage of up to 5 kV, supplied by constant current regulators up to 30 kVA in rating. AGL series transformers provide power to airport lighting luminaires or other loads (resistive) from their secondary circuits.…
Petroleum and natural gas industries — Procedures for testing casing and tubing connections
ISO 13679:2002 establishes minimum design verification testing procedures and acceptance criteria for casing and tubing connections for the oil and natural gas industries. These physical tests are part of a design verification process and provide objective evidence that the connection conforms to the manufacturer's claimed test load envelope and limit loads.
It categorizes test severity into…
Connecting devices for low-voltage circuits for household and similar purposes - Part 1: General req...
This part of IEC 60998 applies to connecting devices as separate entities for the connection of two or more electrical copper conductors (complying with IEC 60228 or IEC 60344) rigid (solid or stranded) or flexible, having a cross-sectional area of 0,2 mm2 up to and including 35 mm2 and equivalent AWG conductors with a rated voltage not exceeding 1 000 V a.c. up to and including 1 000 Hz and 1…
Electrical installations for lighting and beaconing of aerodromes - AGL series transformers
IEC 61823:2002 specifies the characteristics of aeronautical ground lighting series trans-formers (AGLST) used in aeronautical ground lighting for 6,6 A series circuits, at a service voltage of up to 5 kV, supplied by constant current regulators up to 30 kVA in rating. AGL series transformers provide power to airport lighting luminaires or other loads (resistive) from their secondary circuits.…
Installations électriques pour l'éclairage et le balisage des aérodromes - Transformateurs séri...
L'IEC 61823:2002 spécifie les caractéristiques des transformateurs série utilisés pour le balisage aéronautique au sol (AGLST) pour des circuits série de 6,6 A, dont la tension de service atteint 5 kV, alimentés par des régulateurs de courant constant jusqu'à 30 kVA. Les transformateurs série AGL assurent l'alimentation des feux aéronautiques de balisage ou d'autres charges (…