Anaesthetic and respiratory equipment — Conical connectors — Part 1: Cones and sockets
ISO 5356-1:2004 specifies dimensional and gauging requirements for cones and sockets intended for connecting anaesthetic and respiratory equipment, e.g. in breathing systems, anaesthetic-gas scavenging systems and vaporizers.
ISO 5356-1:2004 gives requirements for the following conical connectors:
8,5 mm sizes intended for use in paediatric breathing systems;15 mm and 22 mm sizes intended for…
Industrial automation systems and integration — Product data representation and exchange — Part 215:...
ISO 10303-215:2004 specifies the scope and information requirements for the exchange of ship arrangement definitions, geometric representations of compartments and zones, compartment properties, cargoes, cargo assignments, loading conditions, and damage stability information.
The following are within the scope of ISO 10303-215:2004:
data describing the general subdivision of a ship into spatially…
Standard digital interface for programmable instrumentation - Part 2: Codes, formats, protocols and ...
This Dual Logo International Standard is the result of an agreement between the IEC and the Institute of Electrical and Electronics Engineers, Inc. (IEEE). The original IEEE Standard was submitted to the IEC for consideration under the agreement, and the resulting IEC/IEEE Dual Logo International Standard has been published in accordance with the ISO/IEC Directives. It specifies a set of codes to…
EQUIPMENT FOR FIRE SIGNAL RECEIVING CENTRES AND SYSTEMS
1. SCOPE
1.1 This Standard covers requirements for fire signal receiving centre and systems
which include transmitting, receiving equipment and proprietary fire signal receiving centre
equipment and control unit accessories for use in accordance with the following:
A CAN/ULC-S524, Installation of Fire Alarm Systems;
B CAN/ULC-S561, Installation and Services for Fire Signal Receiving…
Cylinder valve outlets for gases and gas mixtures — Selection and dimensioning
ISO 5145:2004 establishes practical criteria for determining valve outlet connections for gas cylinders.
It applies to the selection of gas cylinder valve outlet connections and specifies the dimensions of a number of them.
ISO 5145:2004 does not apply to connections used for cryogenic gas withdrawal or gases for breathing equipment which are the subject of other International Standards.
Instrument transformers - Part 5: Capacitor voltage transformers
This part of IEC 60044 applies to new single-phase capacitor voltage transformers connected between line and ground for system voltages Um 72,5 kV at power frequencies from 15 Hz to 100 Hz. They are intended to supply a low voltage for measurement, control and protective functions.
The capacitor voltage transformer can be equipped with or without carrier-frequency accessories for power line…
Transformateurs de mesure - Partie 5: Transformateurs condensateurs de tension
La présente partie de la CEI 60044 s'applique aux transformateurs condensateurs de tension monophasés neufs connectés entre la ligne et la terre pour des tensions de réseau Um 72,5 kV aux fréquences industrielles comprises entre 15 Hz et 100 Hz. Ils sont destinés à fournir une basse tension pour les fonctions mesure, commande et protection.
Le transformateur condensateur de tension peut…
Agricultural vehicles — Mechanical connections on towed vehicles — Part 1: Dimensions for hitch ring...
ISO 5692-1:2004 specifies the requirements for the attachment of agricultural non-balanced trailers and implements by means of hitch-rings to the rear of the towing vehicle equipped with either a hook as specified in ISO 6489-1, or a piton-type coupling as specified in ISO 6489-4. Its purpose is to ensure the interchangeability of mechanical connections on agricultural towed vehicles.
Fuel injection equipment — Vocabulary — Part 4: High-pressure pipes and end-connections
ISO 7876-4:2004 establishes a vocabulary for high-pressure pipes and end-connections in fuel injection systems for diesel (compression-ignition) engines.
Medical Electrical Equipment - Part 2-49: Particular Requirements for the Safety of Multifunction Pa...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-49:2001.
1 Scope and object
*1.1 Scope
This Particular Standard applies to the safety requirements of MULTIFUNCTION PATIENT MONITORING EQUIPMENT as defined in subclause 2.2.101.
The scope of this standard is restricted to EQUIPMENT having either more than one APPLIED PART or more than one SINGLE FUNCTION,…