Low-voltage switchgear and controlgear - Part 2: Circuit-breakers
This standard applies to circuit-breakers, the main contacts of which are intended to be connected to circuits, the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c.; it also contains additional requirements for integrally fused circuit-breakers. It applies whatever the rated currents, the method of construction or the proposed applications of the circuit-breakers may be.
Connections for fluid power and general use — Ports and stud ends with ISO 261 metric threads and O-...
ISO 6149-4:2006 specifies dimensions and performance requirements for external hex and internal hex port plugs for use with ISO 6149-1 ports.
Port plugs in accordance with this part of ISO 6149-4:2006 can be used at working pressures up to 63 MPa (630 bar). The permissible working pressure depends upon the plug end size, materials, design, working conditions, application, etc.
Connections for general use and fluid power — Ports and stud ends with ISO 261 threads with elastome...
ISO 9974-4:2006 specifies dimensions and performance requirements for metric external hex and internal hex port plugs for use with ISO 9974-1 ports.
Port plugs in accordance with ISO 9974-4:2006 can be used at working pressures up to 63 MPa (630 bar). The permissible working pressure depends upon the plug end size, materials, design, working conditions, application, etc.
Electromagnetic Compatibility (EMC) - Part 4-34: Testing and Measurement Techniques - Voltage Dips, ...
This National Standard of Canada is equivalent to International Standard CEI/IEC 61000-4-34:2005.
1 Scope
This part of IEC 61000 defines the immunity test methods and range of preferred test levels for electrical and electronic equipment connected to low-voltage power supply networks for voltage dips, short interruptions, and voltage variations.
This standard applies to electrical and…
Compatibilité électromagnétique (CEM) - Partie 4-34: Techniques d'essai et de mesure - Essais d...
La présente norme nationale du Canada est équivalente a la norme internationale CEI/IEC 61000-4-34:2005.
1 Domaine d'application
La présente partie de la CEI 61000 définit les méthodes d'essai d'immunité ainsi que la gamme des niveaux d'essais préférés pour les matériels électriques et électroniques connectés à des réseaux d'alimentation basse tension pour les creux…
Metallic communication cable test methods - Part 4-7: Electromagnetic compatibility (EMC) - Test met...
is suitable to determine the surface transfer impedance and/or screening attenuation and coupling attenuation of mated screened connectors (including the connection between cable and connector) and cable assemblies. This method could also be extended to determine the transfer impedance, coupling or screening attenuation of balanced or multipin connectors and cable assemblies.
Low Voltage Transformers - Part 3: Class 2 and Class 3 Transformers
This CSA Standard is a bi-national Standard with UL 5085-3.
1 Scope
1.1
As noted in Low Voltage Transformers - Part 1: General Requirements, UL 5085-1, or CSA C22.2 No. 66.1, Low Voltage Transformers - Part 1: General Requirements, the requirements in Part 3 cover Class 2 transformers for use with Class 2 circuits in accordance with the National Electrical Code, ANSI/NFPA 70, or the…
Low Voltage Transformers - Part 2: General Purpose Transformers
This CSA Standard is a bi-national Standard with UL 5085-2.
1 Scope
1.1
As noted in Low Voltage Transformers - Part 1: General Requirements, UL 5085-1, or CSA C22.2 No. 66.1, Low Voltage Transformers - Part 1: General Requirements, the requirements of Part 2 cover:
a) Air-cooled transformers and reactors for general use;
b) Autotransformers;
c) Ferroresonant transformers;
d) Cord-…
Low Voltage Transformers - Part 1: General Requirements
This CSA Standard is a bi-national Standard with UL 5085-1.
1 Scope
1.1
These requirements cover the following types of transformers:
a) Air-cooled transformers and reactors for general use;
b) General purpose autotransformers;
c) Ferroresonant transformers;
d) Class 2 and Class 3 transformers (which are evaluated in accordance with Part 3);
e) Cord-connected transformers (which are…