Rechercher

Affiner les résultats
Code de la Classification internationale pour les normes (ICS)
Source
Code de l’organisme d’élaboration de normes (OEN)
Langue
Statut
Code de la Norme nationale du Canada (NNC)
Date de publication

De

à

Affichage 2791 - 2800 de 5907
Small craft — Permanently installed fuel systems
ISO 10088:2009 specifies the requirements for the design, materials, construction, installation and testing of permanently installed fuel systems as installed for internal combustion engines. It applies to all parts of permanently installed diesel and petrol fuel systems as installed, from the fuel fill opening to the point of connection with the propulsion or auxiliary engine on inboard- and…
Éditeur :
ISO
Statut :
Annulée
Date de publication :
2009-08-20
Code(s) de l'ICS :
47.080
Smoke Detectors for Fire Alarm Systems
1.1 This Standard sets forth requirements for smoke detectors and mechanical guards to be employed in ordinary indoor locations in accordance with the following: In the United States: a) National Fire Alarm Code, NFPA 72. In Canada: b) Standard for the Installation of Fire Alarm Systems, CAN/ULC-S524; c) National Building Code of Canada; and d) National Fire Code of Canada. 1.2 A smoke detector (…
Éditeur :
ULC
Statut :
Annulée
Date de publication :
2009-08-13
Code(s) de l'ICS :
13.220.20; 13.320
Electromagnetic compatibility (EMC) - Part 4-14: Testing and measurement techniques - Voltage fluctu...
IEC 61000-4-14:1999+A1:2001+A2:2009 applies to electrical and/or electronic equipment that have a rated input current up to 16 A per phase. Aims to establish a reference for evaluating the immunity of electric and/or electronic equipment when subjected to positive and negative low amplitude voltage fluctuations. Only conducted phenomena are considered, including immunity tests for equipment…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2009-08-11
Code(s) de l'ICS :
33.100.20
Metallic tube connections for fluid power and general use — Part 6: 60 degree cone connectors with o...
ISO 8434-6:2009 specifies general and dimensional requirements for the design and performance of 60° cone connectors and braze-on nipples with or without O-ring sealing, made of steel for tube outside diameters of 6 mm through 50 mm, inclusive, or hose sizes 5 through 51, inclusive. These connectors are for use in fluid power and general applications within the limits of pressure and temperature…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2009-08-06
Code(s) de l'ICS :
23.100.40
Metallic communication cable test methods - Part 4-12: Electromagnetic compatibility (EMC) - Couplin...
IEC 62153-4-13:2009(E) details the method of test to determine the coupling attenuation or screening attenuation for connecting hardware used in analogue and digital communication systems. The test method details means to test one part of a connecting hardware (e. g. wall outlet or plug alone) as well as testing a mated pair of connecting hardware. This publication is to be read in conjunction…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2009-08-05
Code(s) de l'ICS :
33.100.10; 33.120.10
Petroleum and natural gas industries — Downhole equipment — Sand screens
ISO 17824:2009 provides the requirements and guidelines for sand control screens for use in the petroleum and natural gas industries. Included are the requirements for design, design validation, functional evaluation, manufacturing, storage and transport. The requirements of ISO 17824:2009 are applicable to wire-wrap screens, pre-pack screens and metal-mesh screens as defined herein. The…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2009-08-04
Code(s) de l'ICS :
75.180.10
Medical gas pipeline systems - Part 1: Pipelines for medical gases and vacuum
Scope 1.1 This Standard specifies safety requirements for medical gas pipeline systems in health care facilities. It is intended for use by anyone involved in the design, construction, inspection, and operation of medical gas systems. 1.2 The provisions of this Standard are intended to (a) ensure that each medical gas pipeline provides the correct gas or vacuum to the corresponding terminal…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2009-07-31
Code(s) de l'ICS :
11.040.99; 23.040.01
Self-Ballasted Lamps and Lamp Adapters
1 Scope 1.1 These requirements are intended to cover both self-ballasted lamps and self-ballasted lamp adapters rated 120 to 347 V AC nominal for connection to screw-, pin-base, and recessed single contact (RSC or R7) lampholders. These devices are intended for use in accordance with the National Electrical Code, ANSI/NFPA 70, and the Canadian Electrical Code, Part I, in non-hazardous locations…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2009-07-31
Code(s) de l'ICS :
29.140; 29.140
Anaesthetic and respiratory equipment — Laryngoscopes for tracheal intubation
ISO 7376:2009 gives general requirements for laryngoscopes used for intubation, and specifies critical dimensions for the handle and lamp of hook-on type laryngoscopes. It also addresses the interchangeability of blades and handles. It is applicable only to instruments with an internal battery-operated power source for illuminating the larynx, since electrical safety requirements can be more…
Éditeur :
ISO
Statut :
Annulée
Date de publication :
2009-07-30
Code(s) de l'ICS :
11.040.10
High Definition (HD) recording link guidelines
IEC 62546:2009(E) specifies the communication protocol between a TV receiver and a video recorder which are connected through a digital interface.
Éditeur :
IEC
Statut :
Publié
Date de publication :
2009-07-29
Code(s) de l'ICS :
33.160.25; 33.160.40