Plastics piping systems for the supply of gaseous fuels - Unplasticized polyamide (PA-U) piping syst...
ISO 16486-3:2012 specifies the physical and mechanical properties of fittings made from unplasticized polyamide (PA-U) in accordance with ISO 16486-1, intended to be buried and used for the supply of gaseous fuels. It also specifies the test parameters for the test methods to which it refers.
ISO 16486 is applicable to PA-U piping systems the components of which are connected by fusion jointing…
Plastics piping systems for the supply of gaseous fuels - Unplasticized polyamide (PA-U) piping syst...
ISO 16486-5:2012 specifies the requirements of fitness for purpose of the unplasticized polyamide (PA-U) piping system, intended to be buried and used for the supply of gaseous fuels. It also specifies the definitions of electrofusion and butt fusion joints.
ISO 16486-5:2012 specifies the method of preparation of test piece joints and the tests to be carried out on these joints for assessing the…
Road vehicles - Diagnostic communication over Internet Protocol (DoIP) — Part 2: Transport protocol ...
ISO 13400-2:2012 specifies the requirements for diagnostic communication between external test equipment and vehicle electronic components using Internet Protocol (IP) as well as the transmission control protocol (TCP) and user datagram protocol (UDP). This includes the definition of vehicle gateway requirements (e.g. for integration into an existing computer network) and test equipment…
Medical electrical equipment — Part 2-34: Particular requirements for
the basic safety and essential...
201.1.1 *Scope
Replacement:
This particular standard applies to BASIC SAFETY and ESSENTIAL PERFORMANCE of INVASIVE
BLOOD PRESSURE MONITORING EQUIPMENT as defined in 201.3.63, hereinafter referred to as
ME EQUIPMENT.
This particular standard does not apply to catheter tubing, catheter needles, Luer locks, taps
and tap tables that connect to the DOME.
This particular standard does not apply to NON-…
Electromagnetic compatibility (EMC) — Part 3-5: Limits — Limitation of
voltage fluctuations and flic...
1 Scope
This part of IEC 61000 deals with emission of disturbances due to voltage fluctuations and
flicker.
The recommendations in this Technical Specification are applicable to electrical and
electronic equipment that has a rated input current exceeding 75 A per phase and is intended
to be connected to a public low-voltage a.c. distribution system.
Recommendations that specify information…
IEC 61754-20-100:2012(E) covers connectors with protective housings. The housing is defined as variant 4 in IEC 61076-3-106:2006. These connectors use a push-pull coupling mechanism. To connect the fibres inside the housing the LC interface is used as described in IEC 61754-20:2002. The fully assembled variants (connectors) described in this document incorporate fixed and free connectors.
IEC 61754-20-100:2012 covers connectors with protective housings. The housing is defined as variant 4 in IEC 61076-3-106:2006. These connectors use a push-pull coupling mechanism. To connect the fibres inside the housing the LC interface is used as described in IEC 61754-20:2002. The fully assembled variants (connectors) described in this document incorporate fixed and free connectors.
Dispositifs d'interconnexion et composants passifs fibroniques - Interfaces de connecteurs à fi...
IEC 61754-20-100:2012 couvre les connecteurs avec boîtiers de protection. Le boîtier est défini comme la variante 4 de l’IEC 61076-3-106:2006. Ces connecteurs utilisent un mécanisme d'accouplement pousser-tirer. Pour connecter les fibres à l'intérieur du boîtier, l'interface LC est utilisée comme cela est décrit dans l’IEC 61754-20:2002. Les variantes entièrement assemblées (…
Low-voltage switchgear and controlgear assemblies - Part 6: Busbar trunking systems (busways)
IEC 61439-6:2012 lays down the definitions and states the service conditions, construction requirements, technical characteristics and verification requirements for low voltage BTS (see 3.101) as follows:
- BTS for which the rated voltage does not exceed 1 000 V in case of a.c. or 1 500 V in case of d.c.;
- BTS intended for use in connection with the generation, transmission, distribution and…
Installation couplers intended for permanent connection in fixedinstallations
IEC 61535:2009+A1:2012 applies to two up to five wire installation couplers including earth, if provided, with a rated voltage up to and including 500 V a.c. and a rated connecting capacity up to and including 10 mm² for permanent connection in indoor electrical installations. Installation couplers with additional contacts for voltages other than mains voltages are outside the scope of this…