Measurement of fluid flow by means of pressure differential devices inserted in circular cross-secti...
ISO 5167-5:2016 specifies the geometry and method of use (installation and operating conditions) of cone meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit.
As the uncertainty of an uncalibrated cone meter might be too high for a particular application, it might be deemed essential to calibrate the flow meter in accordance with…
Small-bore connectors for liquids and gases in healthcare applications - Part 5: Connectors for limb...
IEC 80369-5:2016 specifies dimensions and requirements for the design and functional performance of small-bore connectors intended to be used for connections in limb cuff inflation applications of medical devices and accessoires. Limb cuff inflation applications include connections between a sphygmomanometer and its cuff. The contents of the corrigenda 1 (2017) and 2 (2021) have been included in…
Connections for fluid power and general use — Hydraulic couplings for diagnostic purposes — Part 2: ...
ISO 15171-2:2016 specifies dimensions, performance requirements, and test procedures for diagnostic couplings with an M16 × 2 connection end that can be connected under pressure without tools to a maximum pressure of 40 MPa (400 bar) providing following stud ends:
? ISO 6149‑2 ? M14 × 1,5;
? ISO 9974‑2 ? M14 × 1,5;
? ISO 1179‑2 ? G 1/4;
? ISO 11926‑2 ? 7/16-20 UNF.
The dimensions of the…
Medical gas pipeline systems — Part 1: Pipeline systems for compressed medical gases and vacuum
ISO 7396-1:2016 specifies requirements for design, installation, function, performance, testing, commissioning and documentation of pipeline systems used in healthcare facilities for the following:
- oxygen;
- nitrous oxide;
- medical air;
- carbon dioxide;
- oxygen/nitrous oxide mixtures (see Note 1);
- helium/oxygen mixtures;
- (*) oxygen 93;
-…
Injection containers and accessories — Part 5: Freeze drying closures for injection vials
ISO 8362-5:2016 specifies the shape, dimensions, material, performance requirements and labelling for the type of closure for injection vials, as described in ISO 8362‑1 and ISO 8362‑4, which is used in connection with the freeze drying (or lyophilization) of drugs and biological materials.
The dimensional requirements are not applicable to barrier-coated closures.
Closures specified in this part…
Anaesthetic vaporizers — Agent-specific filling systems
ISO 5360:2016 specifies requirements, including dimensions, for agent-specific filling systems for agent-specific anaesthetic vaporizers.
ISO 5360:2016 does not specify construction materials.
NOTE 1 For recommendations on materials, see Annex A.
Because of the unique properties of desflurane, dimensions for this agent have not been specified in this International Standard.
NOTE 2…
Small bore connectors for liquids and gases in healthcare applications - Part 6: Connectors for neur...
ISO 80369-6:2016 specifies requirements for small-bore connectors intended to be used for connections in neuraxial applications. Neuraxial applications involve the use of medical devices intended to administer medications to neuraxial sites, wound infiltration anaesthesia delivery, and other regional anaesthesia procedures or to monitor or remove cerebro-spinal fluid for therapeutic or diagnostic…
Safety and control devices for gas burners and gas-burning appliances — Particular requirements — Pa...
ISO 23551-8:2016 specifies the safety, construction and performance requirements for multifunctional controls intended for use with gas burners, gas appliances and similar use, hereafter referred to as "MFC".
ISO 23551-8:2016 is applicable to MFC with declared maximum inlet pressures up to, and including, 50 kPa (500 mbar) of nominal connection sizes up to, and including, DN 150 for use…
1.1
This Standard applies to locking-type, pin and sleeve type plugs, receptacles, power inlets, and connectors and associated integrated accessories (i.e., junction box), rated up to 1,200 amperes (for single- and multi-pole) and above 750 V to 35 kV volts ac, 50/60 Hz and which shall have one or more pilot contacts for multi-pole configuration and above 750 V to 1000 V ac or dc for single pole…