Household and similar electrical appliances - Safety - Part 2-64: Particular requirements for commer...
IEC 60335-2-64:2002+A1:2007+A2:2017 deals with the safety of electrically operated commercial kitchen machines not intended for household use. The rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral, and 480 V for other appliances. Appliances within the scope of this standard are typically used in restaurants, canteens, hospitals and…
Appareils électrodomestiques et analogues - Sécurité - Partie 2-64: Règles particulières pour les ma...
L'IEC 60335-2-64:2002+A1:2007+A2:2017 traite de la sécurité des machines de cuisine électriques à usage commercial non destinées à un usage domestique, dont la tension assignée n'est pas supérieure à 250 V pour les appareils monophasés connectés entre une seule phase et le neutre, et à 480 V pour les autres appareils. Ces appareils sont utilisés, par exemple, dans les restaurants, les…
Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 2: ...
ISO 10077-2:2017 specifies a method and gives reference input data for the calculation of the thermal transmittance of frame profiles and of the linear thermal transmittance of their junction with glazing or opaque panels.
The method can also be used to evaluate the thermal resistance of shutter profiles and the thermal characteristics of roller shutter boxes and similar components (e.g. blinds…
Power capacitors - Low-voltage power factor correction banks
IEC 61921:2017 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 61921:2017 is applicable to low-voltage AC shunt capacitor banks intended to be used for power factor correction…
Power capacitors - Low-voltage power factor correction banks
IEC 61921:2017 is applicable to low-voltage AC shunt capacitor banks intended to be used for power factor correction purposes, possibly equipped with a built-in switchgear and controlgear apparatus capable of connecting to or disconnecting from the mains part(s) of the bank with the aim to correct its power factor. Low-voltage power factor correction banks if not otherwise indicated hereinafter…
Electric vehicle conductive charging system - Part 21-1 Electric vehicle on-board charger EMC requir...
IEC 61851-21-1:2017(E), together with IEC 61851-1:2010, gives requirements for conductive connection of an electric vehicle (EV) to an AC or DC supply. It applies only to on-board charging units either tested on the complete vehicle or tested on the charging system component level (ESA - electronic sub assembly).
This document covers the electromagnetic compatibility (EMC) requirements for…
Household and similar electrical appliances - Safety - Part 2-50: Particular requirements for commer...
IEC 60335-2-50:2002+A1:2007+A2:2017 deals with the safety of electrically operated commercial bains-marie not intended for household use. The rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral, and 480 V for other appliances. the appliances within the scope of this standard are typically used in restaurants, canteens, hospitals and similar…
Electric vehicle conductive charging system - Part 21-1 Electric vehicle on-board charger EMC requir...
IEC 61851-21-1:2017, together with IEC 61851-1:2010, gives requirements for conductive connection of an electric vehicle (EV) to an AC or DC supply. It applies only to on-board charging units either tested on the complete vehicle or tested on the charging system component level (ESA - electronic sub assembly).
This document covers the electromagnetic compatibility (EMC) requirements for…
Système de charge conductive pour véhicules électriques - Partie 21-1: Exigences CEM relatives à la ...
L'IEC 61851-21-1:2017 , ainsi que l’IEC 61851-1:2010, spécifient les exigences relatives à la connexion conductive d’un véhicule électrique (VE) à une alimentation en courant alternatif ou continu. Elle ne s’applique qu’aux unités de charge embarquées soumises à essai soit sur le véhicule complet, soit au niveau des composants du système de charge (SEEE – sous-ensemble électrique/…
Household and similar electrical appliances - Safety - Part 2-99: Particular requirements for commer...
IEC 60335-299:2003+A1:2017 deals with the safety of electrically operated commercial hoods intended for installation above commercial cooking appliances such as ranges, griddles, griddle grills and deep fat fryers, and not intended for household use. The hoods included in this standard are used, for example in restaurants, canteens, hospitals, and commercial enterprises such as bakeries,…