Rechercher

Affiner les résultats
Code de la Classification internationale pour les normes (ICS)
Source
Code de l’organisme d’élaboration de normes (OEN)
Langue
Statut
Code de la Norme nationale du Canada (NNC)
Date de publication

De

à

Affichage 1151 - 1160 de 5903
Railway applications - Electric equipment for rolling stock - Part 3: Electrotechnical components - ...
IEC 60077-3:2019 gives the rules for circuit-breakers, the main contacts of which are connected to DC power and/or auxiliary circuits. The nominal voltage of these circuits does not exceed 3 000 V DC according to IEC 60850. This part of IEC 60077, together with IEC 60077-2, states specifically: a) the characteristics of the circuit-breakers; b) the service conditions with which circuit-breakers…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2019-10-24
Code(s) de l'ICS :
45.060.01
Applications ferroviaires - Equipements électriques du matériel roulant - Partie 3: Composants élect...
L'IEC 60077-3:2019 donne, en complément des règles générales de l'IEC 60077‑2, les règles relatives aux disjoncteurs dont les contacts sont connectés aux circuits à courant continu de traction et/ou aux circuits des auxiliaires. La tension continue nominale de ces circuits n'excède pas 3 000 V CC, conformément à l'IEC 60850. En complément de l'IEC 60077-2, la présente…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2019-10-24
Code(s) de l'ICS :
45.060.01
Railway applications - Electric equipment for rolling stock - Part 4: Electrotechnical components - ...
IEC 60077-4:2019 gives rules for AC circuit-breakers, the main contacts of which are connected to AC overhead contact lines; the nominal voltage of these circuits being in accordance with IEC 60850. This document, together with IEC 60077-2, states specifically: a) the characteristics of the circuit-breakers; b) the service conditions with which circuit-breakers comply with reference to: -…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2019-10-24
Code(s) de l'ICS :
45.060.01
Stationary source emissions — Determination of the mass concentration of carbon monoxide, carbon dio...
This document specifies the fundamental structure and the most important performance characteristics of automated measuring systems for carbon monoxide (CO), carbon dioxide (CO2) and oxygen (O2) to be used on stationary source emissions. This document describes methods and equipment for the measurement of concentrations of these gases. The method allows continuous monitoring with permanently…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2019-10-21
Code(s) de l'ICS :
13.040.40
Installation couplers intended for permanent connection in fixed installations
IEC 61535:2019 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition. IEC 61535:2019 applies to two-wire, up to five-wire installation couplers, including earth, if provided, with a rated…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2019-10-15
Code(s) de l'ICS :
29.120.99
Installation couplers intended for permanent connection in fixed installations
IEC 61535:2019 applies to two-wire, up to five-wire installation couplers, including earth, if provided, with a rated voltage up to and including 500 V AC or DC and a rated connecting capacity up to and including 10 mm2 for permanent connection in electrical installations. Installation couplers with additional contacts for voltages other than mains voltages are outside the scope of this document…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2019-10-15
Code(s) de l'ICS :
29.120.99
Renewable energy and hybrid systems for rural electrification - Part 9-7: Recommendations for select...
IEC TS 62257-9-7:2019 specifies the criteria for selecting and sizing inverters suitable for different off-grid applications integrating solar as an energy source. As well as off-grid system, this document can also apply to inverters where a utility grid connection is available as a backup for charging batteries, but it is not intended to cover applications in which inverters synchronize and…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2019-10-13
Code(s) de l'ICS :
27.160
Simplified design for mechanical connections between precast concrete structural elements in buildin...
This document refers to connections in precast frame systems, either for single-storey or multi-storey buildings. The connections for all orders of joints are considered. Large wall panel and three-dimensional cell systems are not considered. According to the position in the overall construction and of the consequent different structural functions, the seven following orders of joints are…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2019-10-10
Code(s) de l'ICS :
91.080.40
Geotechnical investigation and testing — Geotechnical monitoring by field instrumentation — Part 5: ...
This document specifies the measurement of stress changes by means of total pressure cells (TPC). General rules of performance monitoring of the ground, of structures interacting with the ground, of geotechnical fills and of geotechnical works are presented in ISO 18674‑1. If applied in conjunction with ISO 18674‑4, this document allows the determination of effective stress acting in the ground.…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2019-10-09
Code(s) de l'ICS :
13.080.20; 93.020
Intelligent transport systems — Communication profiles for secure connections between trusted device...
This document specifies a methodology to define ITS-S communication profiles (ITS-SCPs) based on standardized communication protocols to interconnect trusted devices. These profiles enable secure information exchange between such trusted devices, including secure low-latency information exchange, in different configurations. The present document also normatively specifies some ITS-SCPs based on…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2019-10-01
Code(s) de l'ICS :
03.220.20; 35.240.60