Cleanouts
1 Scope 1.1 Inclusions This Standard covers cleanouts, including floor and wall types, used in concealed piping in and adjacent to residential, commercial, industrial, institutional, and other buildings open to the public. 1.2 Illustrations Figure 1 included in this Standard is intended only to describe and portray typical floor and wall type cleanouts and is not intended to restrict design…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2022-06-30
Code(s) de l'ICS :
91.140.80
Automatic electrical controls — Part 2-5: Particular requirements for automatic electrical burner co...
Scope Replacement: This part of IEC 60730 applies to automatic electrical BURNER CONTROL SYSTEMS for the AUTOMATIC CONTROL of burners for oil, gas, coal or other combustibles intended to be used • for household and similar use, • in shops, offices, hospitals, farms and commercial and industrial applications. This International Standard is applicable • to a complete BURNER CONTROL SYSTEM…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2022-06-30
Code(s) de l'ICS :
97.120
Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part...
IEC 61754-20:2012+AMD1:2022 CSV defines the standard interface dimensions for the type LC family of connectors. The changes with respect to the previous edition are to reconsider the whole document and to add Interface IEC 61754-20-9 to IEC 61754-20-16 for a plastic optical fibre (POF). Keywords: LC connectors
Éditeur :
IEC
Statut :
Publié
Date de publication :
2022-06-28
Code(s) de l'ICS :
33.180.20
Dynamic characteristics of inverter-based resources in bulk power systems - Part 2: Sub- and Super-s...
IEC TR 63401-2:2022, which is a technical report, covers the "control interactions" in converter interfaced generators e.g, wind and PV with the frequency of the resulting oscillation below twice the system frequency. SSCI can be categorized into: 1) SSCI in DFIG is caused by the interaction between DFIG wind turbine converter controls and the series compensated network. 2) SSCI…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2022-06-26
Code(s) de l'ICS :
27.160; 27.160
Plastic films for electrical purposes - Part 3: Specifications for individual materials - Sheets 4: ...
IEC 60674-3-4:2022 gives the requirements for polyimide films used for electrical purposes. Materials which conform to this specification meet established levels of performance. However, the selection of a material by a user for a specific application is based on the actual requirements necessary for adequate performance in that application and not based on this specification alone.Safety warning…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2022-06-21
Code(s) de l'ICS :
29.035.20
Electricity metering - Payment systems - Part 31: Particular requirements - Static payment meters fo...
IEC 62055-31:2022 CMV contains both the official standard and its commented version. The commented version provides you with a quick and easy way to compare all the changes between IEC 62055-31:2022 edition 2.0 and the previous IEC 62055-31:2005 edition 1.0. Furthermore, comments from IEC TC 13 experts are provided to explain the reasons of the most relevant changes, or to clarify any part of the…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2022-06-20
Code(s) de l'ICS :
91.140.50
Electricity metering - Payment systems - Part 31: Particular requirements - Static payment meters fo...
IEC 62055-31:2022 applies to newly manufactured, static watt-hour payment meters of accuracy classes 0,5, 1 and 2 for direct connection, for the measurement of alternating current electrical energy consumption of a frequency in the range 45 Hz to 65 Hz that include a supply control switch for the purpose of interruption or restoration of the electricity supply to the load in accordance with the…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2022-06-20
Code(s) de l'ICS :
91.140.50
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-secti...
This document specifies the geometry and method of use (installation and operating conditions) of Venturi tubes[1] when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit. This document also provides background information for calculating the flow rate and is applicable in conjunction with the requirements given in ISO 5167-1. This document…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2022-06-15
Code(s) de l'ICS :
17.120.10
Assessment of lighting equipment related to human exposure to electromagnetic fields
IEC 62493:2015+AMD1:2022 applies to the assessment of lighting equipment related to human exposure to electromagnetic fields. The assessment consists of the induced internal electric field for frequencies from 20 kHz to 10 MHz and the specific absorption rate (SAR) for frequencies from 100 kHz to 300 MHz around lighting equipment. This second edition cancels and replaces the first edition…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2022-06-14
Code(s) de l'ICS :
29.020; 29.140.99
Data quality — Part 82: Data quality assessment: Creating data rules
This document describes how data rules apply to various types of data. Such rules exist to sustain the integrity and reliability of data by capturing requirements into a form that can be processed by databases and other information systems. The following are within the scope of this document: —    fundamental concepts of data rules; —    key characteristics of data rules for common types of data…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2022-06-13
Code(s) de l'ICS :
25.040.40