Rechercher

Affiner les résultats
Code de la Classification internationale pour les normes (ICS)
Source
Code de l’organisme d’élaboration de normes (OEN)
Langue
Statut
Code de la Norme nationale du Canada (NNC)
Date de publication

De

à

Affichage 4691 - 4700 de 6635
Welding consumables — Covered electrodes for manual metal arc welding of stainless and heat-resistin...
ISO 3581 specifies requirements for classification of covered electrodes, based on the all-weld metal chemical composition, the type of electrode covering and other electrode properties, and the all-weld metal mechanical properties, in the as-welded or heat-treated conditions, for manual metal arc welding of stainless and heat-resisting steels. It is a combined standard providing for…
Éditeur :
ISO
Statut :
Annulée
Date de publication :
2003-02-05
Code(s) de l'ICS :
25.160.20
Fibre optic connector interfaces - Part 6-1: Type MU connector family - Simplified receptacle MU-PC ...
IEC 61754-6-1:2003 defines the standard interface dimensions of simplified receptacles for the type MU family of connectors. Keywords: interface dimensions of simplified receptacles for type MU connectors.
Éditeur :
IEC
Statut :
Remplacé
Date de publication :
2003-02-05
Code(s) de l'ICS :
33.180.20
Transportable Mobility Aids
1. Scope 1.1 This Standard specifies (a) general design requirements; (b) product marking and labelling; (c) test procedures; and (d) performance requirements for single-occupancy mobility aids that are intended to be transported in vehicles having a gross vehicle weight rating (GVWR) of less than 7000 kg (15 500 lb) and equipped to accommodate occupants who are seated in a mobility aid. See…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2003-01-31
Code(s) de l'ICS :
11.040.01; 11.040.01
Mobility Aid Securement and Occupant Restraint (MASOR) Systems for Motor Vehicles
1. Scope 1.1 This Standard specifies (a) general design requirements; (b) performance requirements; (c) test methods; (d) requirements for product marking and labelling; and (e) requirements for instructions and warnings for MASOR systems intended for use with forward-facing mobility aids occupied by children and adults with mass of 22 kg or greater, travelling in personally licensed and public…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2003-01-31
Code(s) de l'ICS :
43.040.60; 43.040.60
Safety of power transformers, power supply units and similar - Part 2: Particular requirements for s...
This National Standard of Canada is equivalent to International Standard CEI/IEC 61558-2-1:1997 (first edition 1997-02). 1 Scope Replacement: This part 2 of IEC 61558 applies to stationary or portable, single-phase or polyphase, aircooled separating transformers, associated or not, having a rated supply voltage not exceeding 1000 V a.c., a rated frequency not exceeding 500 Hz, and a…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2003-01-31
Code(s) de l'ICS :
29.180
Safety of power transformers, power supply units and similar - Part 2-2: Particular requirements for...
This National Standard of Canada is equivalent to International Standard CEI/IEC 61558-2-2:1997 (first edition, 1997-10). 1 Scope Replacement: This part 2-2 of IEC 61558 applies to stationary or portable, single-phase or poly-phases, aircooled control transformers associated or otherwise having a rated supply voltage not exceeding 1 000 V a.c. or 1 415 V ripple free d.c. and rated…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2003-01-31
Code(s) de l'ICS :
29.180
Safety of power transformers, power supply units and similar - Part 2: Particular requirements for i...
This National Standard of Canada is equivalent to International Standard CEI/IEC 61558-2-4:1997 (first edition, 1997-02). 1 Scope Replacement: This part 2 of IEC 61558 applies to stationary or portable, single-phase or polyphase, air-cooled isolating transformers, associated or otherwise, having a rated supply voltage not exceeding 1000 V a.c. and rated frequency not exceeding 500 Hz,…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2003-01-31
Code(s) de l'ICS :
29.180
Electricity metering equipment (a.c.) - Particular requirements - Part 23: Static meters for reactiv...
Applies only to newly manufactured static var-hour meters of accuracy classes 2 and 3, for the measurement of alternating current electrical reactive energy in 50 Hz or 60 Hz networks and it applies to their type tests only. For practical reasons, this standard is based on a conventional definition of reactive energy for sinusoidal currents and voltages containing the fundamental frequency only.…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2003-01-28
Code(s) de l'ICS :
17.220.20
Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and i...
Relates to emission and immunity test methods for electrical and electronic equipment using various types of transverse electromagnetic (TEM) waveguides. This includes open (for example, striplines and EMP simulators) and closed (for example, TEM cells) structures, which can be further classified as one-, two-, or multi-port TEM waveguides. The frequency range depends on the specific testing…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2003-01-28
Code(s) de l'ICS :
33.100.10; 33.100.20
Connectors for optical fibres and cables - Part 19-1: Fibre optic patch cord connector type SC-PC (f...
Defines the requirements and quality assessment procedures for the type SC-PC (floating duplex)fibre optic patch cord connector, standard terminated on multimode fibre type A1a and A1b. The contents of the corrigendum of April 2004 have been included in this copy.
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2003-01-27
Code(s) de l'ICS :
33.180.20