Rechercher

Affiner les résultats
Code de la Classification internationale pour les normes (ICS)
Source
Code de l’organisme d’élaboration de normes (OEN)
Langue
Statut
Code de la Norme nationale du Canada (NNC)
Date de publication

De

à

Affichage 3501 - 3510 de 6665
Chain of Custody of Forest-Based Products – Certification Protocol
1 PURPOSE The purpose of this protocol is intended to establish certification program requirements for the chain of custody of forest-based products according to the requirements of either the SFI or PEFC chain of custody standards. Certification of the chain of custody of forest-based products according to these standards will then allow access to a labelling system for targeted SFM…
Éditeur :
BNQ
Statut :
Document de certification
Date de publication :
2009-11-23
Code(s) de l'ICS :
03.100.99; 03.100.99
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures -...
IEC 61300-3-35:2009 describes methods for quantitatively assessing the endface quality of a polished fibre optic connector. The information is intended for use with other standards which set requirements for allowable surface defects such as scratches, pits and debris which may affect optical performance. In general, the methods described in this standard apply to 125 ohmm cladding fibres…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2009-11-19
Code(s) de l'ICS :
33.180.20
Type F and type B residual current operated circuit-breakers with and without integral overcurrent p...
The scope of IEC 61008-1 and IEC 61009-1 applies with the following additions. IEC 62423:2009 specifies requirements and tests for Type F and Type B RCDs (Residual Current Devices). Requirements and tests given in this standard are in addition to the requirements of Type A residual current devices. This standard can only be used together with IEC 61008-1 and IEC 61009-1. Type F RCCBs (Residual…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2009-11-19
Code(s) de l'ICS :
29.120.01; 29.120.50
Live working - Voltage detectors - Part 3: Two-pole low-voltage type
IEC 61243-3:2009 is applicable to hand-held two-pole voltage detectors with its accessories (crocodile clips and detachable leads) to be used in contact with parts of electrical systems: - for a.c. voltages not exceeding 1 000 V at nominal frequencies between 16 2/3 Hz and up to 500 Hz, and/or - for d.c. voltages not exceeding 1 500 V. Voltage detectors covered by this standard are intended to…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2009-11-19
Code(s) de l'ICS :
13.260; 13.260
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures -...
IEC 61300-3-35:2009 describes methods for quantitatively assessing the endface quality of a polished fibre optic connector. The information is intended for use with other standards which set requirements for allowable surface defects such as scratches, pits and debris which may affect optical performance. In general, the methods described in this standard apply to 125 ohmm cladding fibres…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2009-11-19
Code(s) de l'ICS :
33.180.20
Photography and graphic technology — Density measurements — Part 3: Spectral conditions
ISO 5-3:2009 specifies spectral conditions and computational procedures for the definition of several types of ISO 5 standard densities used in imaging applications in photography and graphic technology.
Éditeur :
ISO
Statut :
Publié
Date de publication :
2009-11-19
Code(s) de l'ICS :
37.040.01
Risk management — Principles and guidelines
ISO 31000:2009 provides principles and generic guidelines on risk management. ISO 31000:2009 can be used by any public, private or community enterprise, association, group or individual. Therefore, ISO 31000:2009 is not specific to any industry or sector. ISO 31000:2009 can be applied throughout the life of an organization, and to a wide range of activities, including strategies and decisions,…
Éditeur :
ISO
Statut :
Annulée
Date de publication :
2009-11-12
Code(s) de l'ICS :
03.100.01
Resilient, textile and laminate floor coverings — Classification
ISO 10874:2009 establishes a classification system for resilient, textile and laminate floor coverings. The classification is based on practical requirements for areas of use and intensity of use and is linked to the requirements specified in the relevant International Standard for each type of floor covering. ISO 10874:2009 is also intended to provide guidance for manufacturers, specifiers and…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2009-11-05
Code(s) de l'ICS :
97.150
Standard for Cellulose Fibre Insulation for Buildings
This Standard specifies requirements for treated wood-based cellulose fibre intended for use as thermal insulation (Cellulose Fibre Insulation, CFI) in new and existing buildings within the temperature range of -60 °C to 90 °C. This Standard describes general requirements for the material and additional requirements specific to the types of CFI. The types are specified as Type 1 and Type 2…
Éditeur :
ULC
Statut :
Norme
Date de publication :
2009-10-31
Code(s) de l'ICS :
91.120.10
Protective footwear
Scope 1.1 This Standard deals with new protective footwear and includes requirements for two grades of toe impact resistance, as well as special requirements for sole plate performance, metatarsal protection, electric-shock protection, sole flex durability, conductivity, and chainsaw protection. (See Figures 1 and 2 for footwear and foot nomenclature used in this Standard.) 1.2 This Standard…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2009-10-31
Code(s) de l'ICS :
13.340.10