1 Scope
1.1
This Standard applies to portable luminaires, intended for use in dry, damp, and wet locations, and
intended to be used in accordance with the Rules of the Canadian Electrical Code, Part I, in nonhazardous
locations, on a nominal 120 V system and 15 A or 20 A branch circuits, or on the load side of
a Class 2, LED Class 2, or safety extra-low voltage (SELV) circuit.
1.2
This…
Surge protective devices — Type 4 —Component assemblies
1 Scope
1.1
This Standard covers component assembly surge protective devices (SPDs) consisting of two or more Type 5 components, intended for use in Type 1, 2, or 3 SPD applications.
1.2
Type 4 component assemblies are designed for repeated limiting of transient voltage surges as specified in this Standard on 50 or 60 Hz power circuits over 42 V and not exceeding 750 V.
1.3
The surge protective…
1 Scope
1.1
This Standard applies to decorative lighting strings, decorative lighting outfits, pre-lit trees, and accessories, intended for seasonal or commercial use connected to circuits of 120 V nominal or less by means of an attachment plug, and designed to be used in accordance with the rules of the Canadian Electrical Code, Part I, in non-hazardous locations.
1.2
These requirements…
Sustainability standard for household refrigeration appliances
1.1 This Standard covers two-phase refrigerant compression-type refrigeration appliances for household
use included within the scope of the US Department of the Energy (DoE) and Natural Resources Canada
(NRCan) minimum energy performance requirements. This includes the following product categories:
(a) refrigerators;
(b) refrigerator-freezers;
(c) chest and upright freezers; and
(d) compact…
1.1 General
This Standard specifies requirements for
a) mortar for use in bedding, jointing, and bonding of masonry units; and
b) grout for use in filling core, cell, or cavity space in unit masonry construction.
Notes:
1) The term “unit masonry” refers to masonry construction using clay (shale), calcium silicate (sand-lime), or
concrete masonry units, with individual units not more than 200 mm…
Plume scavenging in surgical, diagnostic, therapeutic, and aesthetic settings
Scope
1.1
This Standard applies to systems and equipment used to capture and evacuate plume. It applies to all settings where such systems and equipment are used, including, but not limited to, the following:
a) surgical facilities;
b) dental clinics;
c) medical offices;
d) veterinary facilities;
e) laboratories and other research and testing facilities;
f) cosmetic…
Scope
1.1
This Standard applies to rigid unplasticized poly (vinyl chloride)* boxes and fittings of the following types that are intended to be installed and used with rigid PVC conduit at a maximum working temperature of 75 °C in accordance with the rules of the Canadian Electrical Code, Part I:
a) junction boxes with an interior volume of 1640 mL+ or less that are intended to provide…
Cylinders, spheres, and tubes for the transportation of dangerous goods
Scope
1.1 General
This Standard covers requirements for the manufacturing, inspection, testing, marking, requalification, reheat treatment, repair, and rebuilding of cylinders, spheres, and tubes (containers) for the transportation of dangerous goods. In addition, it includes the requirements for the qualification of new designs and registration requirements.
1.2 Designations and…
Mobile and fixed offshore units - Electrical installations - Part 6: Installation
IEC 61892-6:2013 contains provisions for electrical installation in mobile and fixed offshore units including pipeline, pumping or 'pigging' stations, compressor stations and exposed location single buoy moorings, used in the offshore petroleum industry for drilling, processing and for storage purposes. It applies to all installations, whether permanent, temporary, transportable or hand…
Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC 60507:2013 is applicable for the determination of the power frequency withstand characteristics of ceramic and glass insulators to be used outdoors and exposed to polluted atmospheres, on a.c. systems with the highest voltage of the system greater than 1 000 V. These tests are not directly applicable to polymeric insulators, to greased insulators or to special types of insulators (insulators…