1.1
This Standard applies to electric motors and generators for installation and use, in accordance with the
Rules of the Canadian Electrical Code, Part I, in non-hazardous locations.
Note: The term “machine” throughout this Standard should be assumed to mean “motor” and “generator”.
1.2
Clauses 2 to 7 are general in nature and apply, unless otherwise noted, to the motors and generators…
1.1
This Standard applies to single- and multiple-conductor fire alarm and signal cables with a maximum
nominal voltage rating of 300 V and a minimum temperature rating of 60 °C for use in buildings and
other structures in dry or damp locations in accordance with the Rules of Sections 16 and 32 of the
Canadian Electrical Code, Part I.
1.2
Because other CSA Group Standards specify…
1.1 This Standard describes the requirements for the design and installation of a fire alarm system with
or without voice communication capability, as defined in Section 3, Glossary.
NOTE 1: This Standard is intended to apply to both required and voluntary fire alarm installations.
NOTE 2: The requirements in this Standard address the installation for various types of fire alarm system…
Shunt capacitors for a.c. power systems having a rated voltage above1 000 V — Part 1: General
This National Standard of Canada is based on International Standard IEC 60871-1:2005, MOD.
This part of IEC 60871 is applicable to both capacitor units and capacitor banks intended to be
used, particularly, for power-factor correction of a.c. power systems having a rated voltage
above 1 000 V and frequencies of 15 Hz to 60 Hz.
This part of IEC 60871 also applies to capacitors intended for…
Information technology - Biometric System-on-Card - Part 1: Core requirements
ISO/IEC 17839-1:2014 establishes
functional architecture of a Biometric System-on-Card
definition of type S1 (fully ISO/IEC 7810 compliant) and type S2 implementation of a Biometric System-on-Card
sensor types in a Biometric System-on-Card
minimum requirements to a Biometric System-on-Card with respect to
discriminative power (i.e. biometric accuracy criteria)
interfaces
power supply options…
Représentation et échange des données relatives aux outils coupants — Partie 201: Création et échang...
La présente partie de l'ISO 13399 spécifie un concept pour la conception des éléments coupants, limité à tous les types de plaquettes régulières, utilisant les propriétés et domaines de valeurs associés.
La présente partie de l'ISO 13399 spécifie une façon commune de concevoir des modèles simplifiés contenant les éléments suivants:
— des définitions et identifications des…
Fibre-optic communication subsystem test procedures - Part 4-2: Installed cable plant - Single-mode ...
IEC 61280-4-2: 2014 is applicable to the measurement of attenuation and optical return loss of installed optical fibre cable plant using single-mode fibre. This cable plant can include single-mode optical fibres, connectors, adapters, splices and other passive devices. The cabling may be installed in a variety of environments including residential, commercial, industrial and data centre premises…
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-1:2014 contains specific requirements for the construction and testing of electrical equipment with the type of protection flameproof enclosure "d", intended for use in explosive gas atmospheres. This standard supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of…
Surge arresters - Part 9: Metal-oxide surge arresters without gaps for HVDC converter stations
IEC 60099-9:2014 applies to non-linear metal-oxide resistor type surge arresters without spark gaps designed to limit overvoltages in HVDC converter stations of two terminal, multiterminal and back-to-back type up to and including an operating voltage of 1 100 kV. The standard applies in general to porcelain-housed and polymer-housed type arresters but also to gas-insulated metal enclosed…
Space data and information transfer systems — Conjunction data message
ISO 19389:2014 specifies a standard message format for use in exchanging spacecraft conjunction information between originators of Conjunction Assessments (CAs) and satellite owner/operators and other authorized parties. Such exchanges are used to inform satellite owner/operators of conjunctions between objects in space to enable consistent warning by different organizations employing diverse CA…